ISS0011R10_A_EN.doc
INTRODUCTION
The user interface consists of the remote control (remote interface) and the display-unit board (local interface). This board must
carry out the following functions:
WITH THE REMOTE CONTROL:
•
Stby/activation (also indicated locally);
•
“General automatic” mode Activation/Deactivation (also indicated locally);
•
Activation/Deactivation mode in cooling;
•
Setting the temperature wanted (Tset);
•
Activation/Deactivation mode in dehumidification;
•
Fan Activation/Deactivation mode;
•
Fan speed selection (Min, Med, Max and Auto);Nighttime Activation/Deactivation mode;
•
Setting the time schedule and operating programmes;
•
Operating programme Activation/Deactivation (also indicated locally);
WITH THE DISPLAY:
•
Stby/activation (also indicated locally);
•
Reset dirty filter alarm;
•
Activation in the “General automatic” mode (at the end of the SELF-TEST programme).
All the above settings must be confirmed by the board by a buzzer sounding briefly (both when enabling and disabling all
functions). The settings to be made with the remote but not mentioned must be ignored.
1.
ELECTRICAL/ELECTRONIC COMPONENTS
•
Vane rotary compressor with a maximum input power of 1.3kW (Inom max 6 A, Isp max 25A);
•
4-speed centrifugal fan motor with a maximum input power of 200W;
•
IR remote control with Olimpia Splendid serial protocol
•
Unico Olimpia Splendid user interface board, from here on in called ‘display unit’;
•
NTC temperature probe with standard cylindrical container and connecting wire
•
Just the one board for the logic control and power section (powering/piloting 230Vac loads);
•
Management of 3 fan speeds by a relay on the board (motor with different stator windings);
•
System control by means of a single temperature probe located in suction on the evaporator side (connected to the
board with a dedicated 2-pole connector);
•
Simplified user interface management (4 LEDs + single key) on the outdoor ‘display’
•
Unidirectional serial communication management with Olimpia Splendid remote control
•
Local/remote control confirm buzzer on the board.