background image

US-ENGLISH

US-ENG- 26

LIMITED WARRANTY USA & CANADA

Thank you for purchasing this Olimpia Splendid USA unit. This unit is covered by a limited 7 year compres-

sor, a 2 year parts warranty and a 1 year limited unit replacement should the compressor fail within the 

first 12 months from date of startup. The warranty periods mentioned above are only in valid if the unit is 

registered within 90 days from date of startup

1

. All units deemed repairable within the warranty period are 

to be shipped to and from an authorized service center at the owner’s expense. Regional service center 

locations can be found on our website. Olimpia Splendid USA will cover all repair expenses.

THIS LIMITED WARRANTY DOES NOT COVER THE FOLLOWING

2

:

1. Damage caused by transportation or handling.

2. Service calls to your home for delivery or pick-up, installation, instruction, replacement of house fuses, connection of house wiring or

plumbing, or to correct unauthorized repairs.

3. Failure of product to perform during power failures and interruptions or inadequate electrical service.

4. Damage caused to the product by accident, vermin, lightning, winds, fire, floods, or any other acts of God.

5.  Damages caused by leaky or broken water pipes, frozen water pipes, restricted drain lines, or inadequate or interrupted water supply.

6. Damages caused by inadequate supply of air.

7. Damages caused by operating the product in a corrosive environment.

8. Repairs when this product is used in other than normal, single family household use or contrary to the instructions described in the

product User manual.

9. Damage resulting from accident, alteration, misuse, abuse, or improper installation, application, repair, or maintenance. Improper

repair includes the use of parts not approved or specified by Olimpia Splendid USA.

10. Normal maintenance as described in the User manual, such as cleaning or replacing filters, cleaning coils, etc.

11. Use of accessories or components that are not compatible with this product.

12. Products with altered or removed serial numbers.

13. Changes in the appearance of the product that do not affect product performance.

14. Increases in utility costs and additional utility expenses.

15. A completed data sheet, available on www.olimpiasplendidusa.com, must be submitted along with the warranty claim if requesting a

replacement unit due to compressor failure. Claims submitted with a missing or incomplete data sheet are subject to delays and/or

warranty rejection

.

DISCLAIMER OF IMPLIED WARRANTIES - LIMITATION OF REMEDIES

CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR 

REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST 

PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. OLIMPIA SPLENDID SHALL NOT BE LIABLE FOR CON-

SEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING 

FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND 

PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR 

LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT 

APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER 

RIGHTS THAT VARY FROM STATE TO STATE.

This warranty is subject to change without notice, please contact us or check our website for latest updates.

*Product Registration Information:

Model Number: ____________________________________

Serial Number:_____________________________________ (See label on the side of the air conditioner).

Date of Purchase: __________________________________

Purchased from: ___________________________________

Installation Company Name:__________________________

Installation Company Phone:__________________________

1 The warranty period for unregistered units will be 5 years for compressor, 1 year on parts and 30 day unit replacement should a compressor fail. To

register your warranty, fill in the information above then mail to the address below. Or you can instantly activate your warranty by submitting it online 

at: https://www.olimpiasplendid.us/warranty-registration

2 The cost of repair or replacement under these excluded circumstances shall be the responsibility of the consumer.

Summary of Contents for Maestro Pro Inverter 12 HP

Page 1: ...ENG INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE Maestro Pro Inverter 12 HP with 2 0 kw electric heat Model 02234 INVERTER 12HP...

Page 2: ...out proper supervision 4 Ifthepowercableisdamaged itmustbereplacedbythemanufacturerorbyitstechnical support service or by similarly qualified personnel to prevent any risk to the user 5 Installation i...

Page 3: ...FRA ENG DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE ESP INSTRUCCIONES DE INSTALACI N USO Y MANTENIMIENTO 1 D E P G O H N L F A B M C...

Page 4: ...min 60mm min 80mm 3 2 min 60mm 2 4 min 100mm 2 4 4 2 3...

Page 5: ...M Y 4 5 B N 8mm 3 6 H H 7 6...

Page 6: ...min 300mm 12 8 9 3 4 202 mm G 162 mm 130 mm G 8 6 5 5 1 10 12 11 G G...

Page 7: ...F D F 13 14 6mm 1 4 15 17 16 18 F E E...

Page 8: ...19 20 E 22 A B 21 W...

Page 9: ...23 A B 26 24 25 L 27 H L L...

Page 10: ...28 29 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a 1c 32 X3 X4 30 31 X1 X2 X2...

Page 11: ...34 J2 J1 33 J2 J1 35 8m 26 36 37...

Page 12: ...41 40 F F2 F1 F F2 F2 F1 F1 43 3 3 42 F min 80mm 3 2 39 3 F 38 10 7...

Page 13: ...44 45 6 min 5 L 5 qts 6a...

Page 14: ...46 47 48 Y2 Y2 Y3 Y3 Y1...

Page 15: ...installations 11 2 6 ENERGY BOOST SYSTEM DRY CONTACT INPUT 12 2 7 UNIT OF MEASURE SELECTION Celsius Fahrenheit 12 3 UNIT OPERATION 13 3 1 WARNINGS 13 3 2 DESCRIPTION OF THE WARNING PANEL 13 3 3 CONTRO...

Page 16: ...RVICE Index Paragraphs marked with this symbol contain very important information and recommendations particularly as regards safety Failure to comply with them may result in danger of injury to the o...

Page 17: ...contains useful information for understanding the use and programming of the conditioner and themost common maintenance interventions 2 This document contains proprietary information protected by law...

Page 18: ...he appliances and respect anything suggested by common sense and those of the Safety Norms in force in the place of installation 10 Always wear Personal Protection Devices when servicing the unit Thes...

Page 19: ...1 3 RECEIPT AND UNPACKING The products are packaged by qualified personnel using suitable packaging material The units are shipped complete and in perfect condition when leaving our facility However...

Page 20: ...selecting an air conditioner or heat pump it is essential to make an accurate calculation of the heat load including sensible and latent gains for cooling mode and for heat pumps the sensible loss for...

Page 21: ...e supply air flap fig 3 j Do not place bottles cans clothes flowers or any other object on the return air grille fig 3 k Do not install the unit directly on another household appliance TV radio fridge...

Page 22: ...the outside 2 4 2 Preparing the condensate discharge fig 6 7 A condensation drain line N must be inserted into the connection which can be accessed after opening the door under the unit and connected...

Page 23: ...17 d Insert the two caps with spring on the front part of the external grille on its two housings pulling until it clicks fig 18 and couple the two chains to the large eyelet of the spring e Using one...

Page 24: ...plate of the unit The power supply line is fitted with an efficient earth connection that is ap propriately sized for the maximum absorption of the conditioner minimum cross section of the cable must...

Page 25: ...in the terminal board J2 fig 34 m Lock the cable with the clamp J1 fig 34 n Close the switchgear o Reassemble the front cover The above operation must be performed by a qualified and properly license...

Page 26: ...st be performed by the installer or similarly qualified service technician as per local state and or national requirements To prevent the risk of an electric shock unplug or de energize the unit befor...

Page 27: ...4 1 2 The unit must not be installed in rooms where explosive gas could be present or where there are conditions of heat and humidity beyond the maximum limits indicated in the technical specificatio...

Page 28: ...N RED X Dehumidification mode ON BLUE X Ventilation mode OFF X Spa mode auto mode X X High fan speed X X Medium fan speed X X Low fan speed X X Automatic fan speed X X Timer enabled X X ON Filter dirt...

Page 29: ...t cover b Insert the batteries into the compartment Check the polarity of the batteries as indicated on the bottom of the compartment c Close the compartment fig 36 3 4 2 Replacement the batteries Bat...

Page 30: ...t together with button B7 to change temperature unit F C B7 Desired clock programming temperature decrease Press it together with button B6 to change temperature unit F C B8 Activation deactivation of...

Page 31: ...in switch off or unplugging the unit 3 6 4 Operation in Cooling mode only When used in this mode the unit dehumidifies and cools the room To activate this mode press several times the button B5 on the...

Page 32: ...iod before stopping then both air flaps close May be equipped with a electric heater that activates automatically as a back up source of heat to the compressor when operating in low ambient external t...

Page 33: ...se timers first set the correct time see paragraph 3 6 13 and then set the timer as you prefer 3 6 13 Timer and clock setting To set time operate the remote control as follows a Press B9 button Set ti...

Page 34: ...to one of the two programs or both In particular each time you press button B9 Set timer Programs activation situation changes as follows Use of Program 1 only Use of Program 2 only Use of Programs 1...

Page 35: ...eration of unit the air filter has to be cleaned periodically The air filter is at the top of the unit Filter removal a Unplug or disconnect the unit from power b Switch off the unit and wait for the...

Page 36: ...installation and operating instructions 4 2 2 Condensate water drainage in case of emergency Should the condensation management system get clogged or stop draining the unit stops and displays alarm c...

Page 37: ...a blackout occur alarm code 50 will appear 4 3 3 Console alarms If one of the following alarms on the unit control display persists for more than three minutes please contact an Olimpia Splendid autho...

Page 38: ...y Clean the air filter The doors or windows are open Close the doors or windows The air inlet or outlet vents of the indoor or outdoor units are blocked First remove the obstructions and then re start...

Page 39: ...tarting the unit verify Supply Voltage to the unit _______ Install batteries in Remote Control Start Unit to verify operation and record requested values below The following values are to be recorded...

Page 40: ...not affect product performance 14 Increases in utility costs and additional utility expenses 15 A completed data sheet available on www olimpiasplendidusa com must be submitted along with the warranty...

Page 41: ...264098A Contact Information Olimpia Splendid USA 870 International Parkway Suite 120 Flower Mound TX 75022 Phone 800 408 5196 Ext 103 Email customerservice olimpiasplendidusa com...