43
3.2
Internal unit assembly
IMPORTANT: The cooling and condensate pipes may be
connected only in the positions indicated in the overall
dimensions.
3.2.1 Fixing plate
The fixing plate onto which the internal unit is to be hooked
must be positioned keeping in mind the applianceis
dimensions indicated. Assemblage should be carried out as
follows:
a) The plate is fixed to the wall in the selected location by
means of the four blocks and screws supplied. Other
types of screws and blocks may also be used (Ø 8 mm),
as long as they have a raised head. If the wall onto which
the plate is to be fixed is made of wood then the plate
must be attached with wooden screws with a raised
head and a 5,5 mm diameter.
b) Tighten the screws slightly.
c) Use a water level to level the plate (fig. 3).
d) Tighten the srews completely.
e) Check the plateis stability by pulling it downwards and to
the side.
120 mm
350 mm
Fig. 1 bis
CEILING
Fig. 2
Fig. 3
CEILING