IMTP 2.2 - ITTP 2.2/4/5.5/7.5 

    

ENG

 

 

INDEX 

1.

      

SPECIFICATIONS .......................................................................................................................  3

 

2.

      

WORKING OPERATIONS ...........................................................................................................  3

 

2.1   STRUCTURE OF A FREQUENCY CONVERTER ..............................................................  3

 

3.

 

WORKING CONDITIONS ..........................................................................................................  4

 

4.

 

WARNINGS AND RISKS ...........................................................................................................  4

 

5.   ASSEMBLING AND INSTALLATION ............................................................................................  5

 

5.1    Fixing measures ................................................................................................................  5

 

5.2

 

Pump hydraulic connection ...............................................................................................  6

 

5.3

 

Electric connections ..........................................................................................................  6

 

5.4    Motor-pumps phases connection .......................................................................................  6

 

5.5

 

Electric connection to Line and Motor ................................................................................  7

 

5.6

 

Pressure transducer connection, on different types ...........................................................  8

 

5.7    Connections on the electronic board .................................................................................  9

 

6.

 

STARTING AND PROGRAMMING ..........................................................................................  12

 

6.1    First Inverter Using Ð Self Regulation procedure .............................................................  12

 

6.2    UserÕs check after Inverter setting ...................................................................................  12

 

6.3

 

Programming Functions ..................................................................................................  13

 

6.4

 

Alarms .............................................................................................................................  16

 

6.5    Group Functioning - data transmission via serial bus RS485 ...........................................  16

 

6.6    Replacing the battery .......................................................................................................  17

 

7.

 

SOLUTION OF THE MOST COMMON PROBLEMS ................................................................  17

 

8.

 

GUARANTEE ...........................................................................................................................  18

 

9. 

DICHIARAZIONE DI CONFORMITAÕ / 

DECLARATION OF CONFORMITY

.............................  19 

 

 

Summary of Contents for IMTP 2.2 M-RS

Page 1: ...Motor Pump Inverter Type IMTP 2 2 M RS ITTP 2 2 M RS ITTP 4 M W RS ITTP 5 5 M W RS ITTP 7 5 W RS ENG Operation and maintenance handbook...

Page 2: ...5 Electric connection to Line and Motor 7 5 6 Pressure transducer connection on different types 8 5 7 Connections on the electronic board 9 6 STARTING AND PROGRAMMING 12 6 1 First Inverter Using Self...

Page 3: ...0mA or 0 5V output The control logic works with an output of 5 or 15V switchable that supplies the pressure transducer MINIMUM FLOW WORKING PROTECTION to prevent a closed delivery working the control...

Page 4: ...ty regulations could endangers others and damage the devices which can lead to loss of warranty The results of the non observance of the security rules can be Malfunctioning of the system Danger to ot...

Page 5: ...to remove the paint from the contact surface It is necessary to avoid ground loop that is like an antenna for EMC emission Power supply must be admitted on working condition don t lift or carry the m...

Page 6: ...ic system Before working be certain all the circuit is without voltage also the connections voltage clear Disconnect the inverter from the power supply before working on electrical or mechanical parts...

Page 7: ...wo cables connectors from the logic board J1 26 poles e J2 4 poles for IMTP2 2 ITTP2 2 Figure 5 or J5 26 poles for ITTP4 7 5 Figure 8 Connect the 3 motor terminals U V W on the power board on IMTP2 2...

Page 8: ...nnectors for IMTP ITTP2 2 fig 5 and J9 for ITTP4 7 5 fig 8 if previously disconnected making sure they are firmly fixed don t forget the clamp on J9 for ITTP4 7 5 fig 8 Replace and close the box using...

Page 9: ...9 IMTP 2 2 ITTP 2 2 4 5 5 7 5 ENG 5 7 Connections on the electronic board Figure 5 Logic board of IMTP2 2 ITTP 2 2...

Page 10: ...10 IMTP 2 2 ITTP 2 2 4 5 5 7 5 ENG Figure 6 Power board of IMTP 2 2 Figure 7 Power board of ITTP 2 2...

Page 11: ...11 IMTP 2 2 ITTP 2 2 4 5 5 7 5 ENG Figure 8 Logic board of ITTP 4 7 5 Figure 9 Power board of ITTP 4 7 5...

Page 12: ...pump is fully of water and close completely the outlet of the pump Pressing START for the Self Regulation Check for the registration of the curve of the pump for the regulation of the stop for closed...

Page 13: ...after the variation press ENTER Decrease the reference pressure during functioning ESC To exit to the function and automatically saving START Pump start STOP Pump stop If pressed with the key during...

Page 14: ...iangle see 5 3 Set the rotation direction 0 1 Default 0 Regulation of the minimum flow power for the motor stop in closed output condition Regulation of the dry working power stop default 80 Pump data...

Page 15: ...flow stop Default 12 second 15 second for ITTP4 7 5 4 Re start delay time after minimum flow stop Default 1 second 5 Dry working stop delay time for pump filling Default 40 seconds 6 When cos go down...

Page 16: ...faulty current control Automatic re start final stop after 10 consecutive events 13 Input Voltage under limit Input voltage under the minimum working limit Automatic re start final stop after 10 cons...

Page 17: ...output power to the motor then stop the motor and the inverter show Over Temperature IGBT alarm Inverter Temperature alarm Temperature of the electronic board of the inverter is too high and the inve...

Page 18: ...at pump haven t any defect fault seal impellers etc that can cause a big power absorbing also without water in dry condition 13 A group of two or more inverters cannot communicate between each other i...

Page 19: ...ctives and to national law following the technical standards Machines 98 37 CE Low Voltage 73 23 CE e successive modifiche and subsequent amendments IEC EN 61000 6 1 CEI EN 61000 6 4 ETSI EN 301 489 1...

Page 20: ...na Ind Esmoriz Sector C 8 36 13 86 O GPS OLIJU Manufacturing 40 57 27 11 N PORTUGAL PORTUGAL 4520 475 Rio Me o Zona Industrial de Rio Me o Avenida Santiago N 43 40 57 37 20 N 8 35 50 10 O GPS OLIJU Co...

Reviews: