12-TROUBLESHOOTING
MALFUNCTION
POSSIBLE CAUSE
PROCEDURE
Flush plate flashes red after flushing
• Low energy level
• Recharge battery
Flush plate flashes red and doesn’t flush
• Extremely low energy level
• Recharge battery
• Faulty mechanism
• Replace flush mechanism
• Obstructed servomotor
• Check the flush mechanism (outlet
valve) configuration
Frequent low battery (red flashes) indication
• Clogged filter
• Verify/clean the filter
• Faulty hydro generator
• Replace hydro generator
When interacting with the flush plate, lighting works
but no flush is performed
• Faulty software
• Reboot system
• Servomotor misconnection
• Check connections
• Faulty servomotor
• Replace servomotor
• Empty cistern
• Check angle valve
• Check for eventual blocking in the
filling mechanism (inlet valve)
• Check for water in the grid
When interacting with the flush plate, lighting doesn’t
work but a flush is performed
• Faulty software
• Reboot system
• LED function deactivated
• Check LED function setting
When interacting with the flush plate, lighting doesn’t
work and no flush is performed
• Faulty software
• Restart system
• Drained battery
• Recharge battery
• Misconnections
• Check connection with hydro
generator
• Faulty hydro generator
• Replace hydrogenate
• Poor calibration
• Reboot system
• Faulty sensor
• Replace sensor / flush plate
When interacting with the flush plate, two flashes in
both sensors are presented and no flush is performed
• Cleaning mode activated due to poor
calibration
• Reboot system
• Excessive condensation inside the flush plate
• Verify / clean flush plate interior
Ceramic bowl cleaning is not effective
• Flush volumes may be set incorrectly
• Check the flush mechanism (outlet
valve) configuration
• Check if the filling mechanism (inlet
valve) is performing correctly
Water runs continuously in ceramic bowl
• Faulty software
• Reboot system
• Faulty rubber sealing
• Replace rubber sealing
• Faulty flush system
• Replace flush system
• Faulty filling mechanism (inlet valve)
• Replace filling mechanism (inlet valve)
Unprovoked flushes
• Hygienic automatic flush activated
• Verify hygienic automatic flush
function setting
• Poor calibration
• Reboot system
Incorrect flushes
• Faulty software
• Reboot system
• Dirty or wet flush plate
• Verify / clean flush plate interior
• Poor calibration
• Reboot system
Charger doesn’t show green light
• Faulty wall charger
• Replace the wall charger
• Faulty hydro generator
• Replace hydro generator
Summary of Contents for NO-TOUCH
Page 1: ...NO TOUCH User manual Bedienungsanleitung Инструкция по применению AC10000879611 4 ...
Page 2: ......
Page 4: ...4 ...
Page 20: ...20 EN RU DE Remove hydro generator 3 wash thoroughly with water on both sides 4 ...
Page 38: ...38 Entferne den Hydrogenerator 3 Gründlich mit Wasser auf beiden Seiten waschen 4 EN RU DE ...
Page 56: ...56 Снимите гидрогенератор 3 Тщательно промойте водой с обеих сторон 4 EN RU DE ...
Page 59: ...SAVE ...