Report No. 550536CHI-001
Page 17
Issued: 06/13/95
David B. Knight & Associates, Inc, DBA Ole Hickory Pits
Revised: 10/11/11
J)
Minimum lettering height of 0.10 inch with a minimum vertical spacing between lines of 0.066 inch:
Minimum clearance from combustible construction minimum 2 inches from sides and back. Minimum
6” from floor.
K)
Instructions for lighting and shutdown the appliance. Lighting instructions specify a 5-minute
complete shutoff period before the appliance is re-lighted.
L)
"This equipment is to be installed to comply with the applicable Federal, state or local plumbing codes
having jurisdiction." and Cet équipement doit être installé pour se conformer aux codes de plomberie
applicable fédérale , provinciales ou locales ayant compétence"
M)
The word "NOTICE" and "Avis" in letters having a minimum lettering height of .36 inches. The
remainder of the marking has a minimum lettering height of 0.180 inch with a minimum vertical
spacing between lines of 0.069 inch, the lettering is in black, on a yellow background, where visible
after installation:
"NOTICE: When this appliance is installed with casters, it must be installed with the casters supplied,
a connector complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick disconnect device
complying with either ANSI Z21.41 or CANI-69. It must also be installed with a restraining means to
guard against transmission of strain to the connector, as specified in the appliance manufacturer's
instructions." And “AVIS: Les appareils sur roulettes doivent être pourvus des roulettes fournies, d’un
tuyau de raccordement conforme à la norme ANSI Z21.69 ou CAN/CGA 6.16 et d’une raccord à
débrancement rapide satisfaisant les exigencies de la norme ANSI Z21.41 ou CAN1-6.9. lls doivent
aussi être minis d’un dispositif de retenue pour empêcher toute transmission de tension au tuyau de
raccordement confromément aux instructions du fabricant.” Provided only on units shipped with
casters.
N)
"Warning" followed by "Electrical Grounding Instructions" followed by "This appliance is equipped
with a three-prong (grounding) plug for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong
from this plug." And “Cet appareil est pourva d’une fiche à trios broches dont une mise à la terre
assurant une protection contre les chocs électriques. La prise dans laquelle elle est branchée doit être
correctement mise à la terre. Ne pas couper ni enlever la broche de mise à la terre de la fiche.”
Provided only on units, which are cord connected to the supply source.
O)
Wiring Diagram provided on the unit, where accessible during servicing of electrical components.
Provided only on units with electrical components.
P)
Instructions for lubrication of the fan motor, or a statement that the bearings are permanently
lubricated, located on the fan housing
The minimum dimension for all letters of the word Caution or similar words conveying a warning are
3/32 inch (2.4 mm) high. "WARNING" and "Attention" in contrasting color from background.
Q)
"EVAC Off/On" by EVAC motor switch when EVAC motors are used.
R)
"CAUTION, Use Only Dry Seasoned Wood!" and “Attention N’utiliser que du bois sec” marked on
fire box door.
S)
"Suitable for outdoor use" and "Convient pour une utilisation en extérieur"