![background image](http://html1.mh-extra.com/html/oldham/sharpeye-np40igb/sharpeye-np40igb_user-manual_3710846039.webp)
40
Dust
•
Designed to meet MIL-STD-810C, method 510.1,
procedure I
•
Exposure to a dust concentration of 0.3
frames/cubic ft. at a velocity of 1750 fpm, for 12
hours
Vibration
•
Designed to meet MIL-STD-810C, method 514.2,
procedure VIII
•
Vibration at an acceleration of 1.1g within the
frequency range of 5-30 Hz, and an acceleration of
3g within the frequency range of 30-500 Hz
Mechanical Shock
•
Designed to meet MIL-STD-810C, method 516.2,
procedure I
•
Mechanical Shock of 30g half-sine wave, for 11
msec
Electromagnetic
Compatibility (EMC)
This product is in conformance with EMC directive
89/336/EC:
•
Conducted Disturbances: IEC/EN61000-4-6
•
ESD: IEC/EN61000-4-2
•
Burst: IEC/EN61000-4-4
•
Surge: IEC/EN61000-4-5
•
Immunity to main supply voltage variations: MIL-
STD-1275B
•
Radiated Immunity – IEC/EN61000-4-3
•
Conducted Immunity – IEC/EN61000-4-6
B
Wiring Instructions
B.1
General Instructions for Electrical Wiring
Follow the instructions detailed in this section for determining the correct wire gauge to be
used for the installation.
35
Use Table 25 to determine the required wire gauge /size for general wiring, such as
relay wiring. Calculate the permitted voltage drop with respect to load current, wire
gauge and length of wires.
Table 25: Maximum DC resistance at 68°F (20ºC) for copper wire
AWG #
mm2
Ohm per 100 ft
Ohm per 100 m
26
0.12 - 0.15
4.32
14.15
24
0.16 - 0.24
3.42
11.22
22
0.30 - 0.38
1.71
5.60
20
0.51 - 0.61
1.07
3.50
18
0.81 - 0.96
0.67
2.20
16
1.22 - 1.43
0.43
1.40
14
1.94 - 2.28
0.27
0.88
12
3.09 - 3.40
0.17
0.55
10
4.56 - 6.64
0.11
0.35
Summary of Contents for SharpEye NP40IGB