3-10
3.6.
Amp Unit
■
What is the Amp Unit?
“Amp Unit” is composed of individual axis current board, IPM, heat sink and current
sensor.
A1600
Ⅲ
N
、
A1800N A700
Ⅲ
N
Servo amp
Board
IPM type
Board
IPM type
R axis
RC507
PM200CL1A060 RC504
PM100CL1A060
D axis
RC507
PM200CL1A060 RC504
PM100CL1A060
O axis
RC507
PM200CL1A060 RC504
PM100CL1A060
T axis
(
C axis
)
RC508 PS21765
RC508 PS21765
Current board is connected with IPM as shown below.
・
R,D,O axes
:
By connector
・
T (C) axes
:
By soldering
(Example) Amp unit of R, D, O for A1600V and A1800V
RC507