background image

Any information contained in these operating instructions may be changed without prior notice.

OKM does not make any warranty for this document. This also applies without limitation to implied assurances of 

merchantability and fitness for a specific purpose. OKM does not assume any responsibility for errors in this manual 

or for any incidental or consequential damage or loss associated with the delivery, exploitation or usage of this 

material.

This documentation is available "as presented" and without any kind of warranty. In no circumstances OKM takes 

responsibility for lost profits, usage or data loss, interruption of business activities or all kind of other indirectly 

damages, which developed because of errors in this documentation. This instruction manual and all other stored 

media, which are delivered with this package should only be used for this product. Program copies are allowed only 

for security- and safety purposes. The resale of these programs, in original or changed form, is absolutely forbidden.

This manual may not be copied, duplicated or translated into another language, neither in part nor completely, over 

the copyright matters without the prior written consent of OKM.

Copyright ©2002 – 2011 OKM GmbH. All rights reserved.

Summary of Contents for Bionic X4

Page 1: ...FS Future Series Bionic X4 Version 1 0 User s Manual...

Page 2: ...ranty In no circumstances OKM takes responsibility for lost profits usage or data loss interruption of business activities or all kind of other indirectly damages which developed because of errors in...

Page 3: ...1 Control Unit 10 2 2 Laser 10 2 3 Data Transfer 10 3 Scope of delivery 11 4 Control elements 13 4 1 Control Unit 14 4 2 Wireless Headphones 16 5 Assembly 17 6 Operating modes 21 6 1 Bionic Scan 23 6...

Page 4: ...the USB cable to the Smart Phone 20 Figure 5 8 Switch on the Bionic X4 20 Figure 5 9 Start the measurement 20 Figure 6 1 Complete menu structure 22 Figure 6 2 Contact between operators hand and the e...

Page 5: ...1 Introduction CHAPTER 1 Introduction...

Page 6: ...epth size and displacement Especially in very wet soils like clay and sand with high conductivity or attenuation of the ground In certain conditions recording of the measured results can be falsified...

Page 7: ...l any possible condensation has evaporated The unit is not weather proof and water moisture or condensation can destroy the unit Avoid strong magnetic fields which may occur in places where there are...

Page 8: ...back Note the color of the ground close to the surface A red or reddish color of the ground is an indicator of rust traces As regards to the finds themselves you should definitely pay attention to the...

Page 9: ...2 Technical specifications CHAPTER 2 Technical specifications...

Page 10: ...smart phone at USB approx 16 hours Operating time smart phone at USB approx 8 hours Operating temperature 0 C to 70 C Feedback acoustical visual Processor Atmel AtMega CPU 14 7 MHz 2 2 Laser Laser be...

Page 11: ...3 Scope of delivery CHAPTER 3 Scope of delivery...

Page 12: ...parts of the Bionic X4 Description Quantity Control unit 1 Wireless headphones including 2 batteries AAA 1 Android Smart Phone and included accessories 1 Power Pack incl charger and traveling adapter...

Page 13: ...elements CHAPTER 4 Control elements In this section you will learn more about the fundamental use of all control elements for this measuring instrument All connections inputs and outputs are explained...

Page 14: ...energy which influences the whole measurement Connector for Power Pack The Bionic X4 has no internal batteries but uses the external Power Pack Additional information about the usage and care of the P...

Page 15: ...surement results Calibration Control This regulator is used to calibrate the device during the bionic measurement to adjust it for the current environment Holder for Smart Phone When using the Bionic...

Page 16: ...teries correctly Now place the protective cap again on the battery case and press carefully until it snaps into place Power on the wireless headphones with the power on off button ON OFF and find the...

Page 17: ...5 Assembly CHAPTER 5 Assembly In this section is explained how to assemble the device and how to prepare a measurement...

Page 18: ...Connect the cable of the Power Pack with the device Figure 5 2 Switch on the Power Pack Step 2 Switch on your Power Pack The LED on your Power Pack should light up in green now If the LED shows red yo...

Page 19: ...the application on the Smart Phone Step 5 Now run the application on the Smart Phone by touching the Bionic icon with your finger You should turn the holder into the required position and fix it with...

Page 20: ...le with the Bionic X4 switched off As soon as the USB cable is connected and the Power Pack is switched on charging takes place Figure 5 8 Switch on the Bionic X4 Step 8 Switch on the Bionic X4 by usi...

Page 21: ...6 Operating modes CHAPTER 6 Operating modes In this section you will learn more about operating the device Every operating mode will be explained in a proper subsection...

Page 22: ...l as the magnetic field of earth Ionic Scan Measurement for long time buried gold objects LED Light Switch the LED lights on and off Laser Switch the laser pointer on and off To switch between the men...

Page 23: ...6 2 shows an example of how to hold the unit Turn the calibration control from one side to the other very slowly until a higher value is seen The upper value of 255 is too high and must be lower For t...

Page 24: ...y calibrated the unit and the operating mode is active you can begin your scan In a left to right and horizontal to downward motion as shown in Figure 6 4 move the Bionic X4 Do not move the unit too q...

Page 25: ...nduct the scans without the Smart Phone When using the Smart Phone and the integrated camera you can get assistance and an exact direction from the Smart Phone application which will help you greatly...

Page 26: ...n in Figure 6 7 As soon as you have located a possible object then the symbol of gold coins will be displayed This is the correct direction for the first picture to be taken Wait until the symbol is s...

Page 27: ...ons are correct There where the two images are a triangulation can be made and this will be the point of highest probability Clicking again the trigger on the hand grip will clear the images so that y...

Page 28: ...m The unit will calibrate itself automatically for the chosen ionic stream field Please pay particular attention to the background that it is clear of any foreign objects or debris Foreign objects or...

Page 29: ...ave to be done to correctly triangulate the buried object 6 2 3 Scan with activated Smart Phone When you have the Smart Phone connected the same for the Ionic mode pertains as with the Bionic mode You...

Page 30: ...ver point it at people or animals Laser radiation can cause damage to eyes or skin Lasers should never be used by children They are not toys This product is equipped with a class 3R laser according to...