5
HARDWARE RS485 WITH PTZ KEYBOARD SETUP
Default protocol is Pelco-D and default baud rate is 9600 for RS485 communication between
camera and PTZ controller.
NOTE: It is highly recommended that you run an additional cable for your RS485
communication from your camera. Some models may have RS485 setting in menu. Please
leave RS485 baud rate setting at 38400.
OSD OPERATION
OSD Main Menu
The menu consists of a main menu and sub-menu. Each
menu has a total of seven sub-menus of the camera
functions. Each sub-menu, the sub menu back to the
primary and secondary and tertiary sub-menu consists
of ENTER through the key mark from the primary to the
secondary can be moved to the third sub-menu.
1. LENS: Lens Mode Setting
1.
VIDEO: VIDEO IRIS LENS drive is used.
2.
MANUAL: MANUAL IRIS LENS mode when you
apply FIXED TYPE lens, it can used, 2.1mm ~
50mm lens can be applied to a variety of lens.
3.
DC: AUTO DC IRIS lens, if applicable, DC IRIS
MOTOR driven by the Open the aperture is
closed. Indoor mode (INDOOR) and outdoor (OUTDOOR) In the sub-modes can be
adjusted.
2. LENS: Lens Mode Setting
1.
SHUTTER: AUTO, MANUAL is set to
a.
AUTO
b.
1/30(25);1/60(50); 1/120(100); 1/240;
1/500; 1/1000; 1/2000; 1/5000;
1/10000; 1/50000
c.
DSS Mode conversion: DSS (Digital
Slow Shutter) to set the value: x2, x4,
x6, x8, x10, x15, x20, x30, x60
Summary of Contents for HD21T-K10