![OKIDATA Microline ML395 Handbook Download Page 78](http://html1.mh-extra.com/html/okidata/microline-ml395/microline-ml395_handbook_3647649078.webp)
Cancel
ASCII: CAN
Dec: 24
Hex: 18
Clears buffer and cancels single double-width set by SO or ESC
SO command; does not affect custom characters or other
commands.
Print Suppress Mode
On
ASCII: ESC Q n
Dec: 27 81 n
Hex: 1B 16 n
Prints out data in print buffer and puts printer in Print Suppress
Mode until DC1 command is received.
Command will be ignored unless Print Suppress Effective item in
Menu is set to Yes.
n = 23
Print Suppress Mode
Off
ASCII: DC1
Dec: 17
Hex: 11
Cancels Print Suppress Mode. Printer becomes active, processes
all data received.
Stop Printing
ASCII: ESC j
Dec: 27 106
Hex: 1B 6A
Deselects the printer. Press SELECT to reactivate. No data is lost.
Disable Paper-Out
Sensor
ASCII: ESC 8
Dec: 27 56
Hex: 1B 38
Paper-out sensor is deactivated: printer will print to next top of
form before registering paper end error.
This command will be ignored if the Paper Out Override in Menu
is set to No (the factory default).
Enable Paper-Out
Sensor
ASCII: ESC 9
Dec: 27 57
Hex: 1B 39
Sensor detects when less than 1/2" of paper is left. When PAPER
OUT light is on, pressing SELECT prints 1 line of data at a time
until top of form position on next page is reached. Sensor can also
be controlled by the Menu.
ML395 ( 96-02-07 )
Summary of Contents for Microline ML395
Page 1: ...Chapter 0 Front Cover ML395 96 02 07...
Page 28: ...Chapter 5 Control Panel Indicator Lights Control Panel Indicator Lights ML395 96 02 07...
Page 29: ...Control Panel Buttons Menu Mode ML395 96 02 07...
Page 30: ...Control Panel Buttons Print Mode Control Panel Buttons Print Mode ML395 96 02 07...
Page 51: ...ML395 96 02 07...