background image

Reactivity Data

Stability: Stable

Polymerization: Will not occur.

Hazardous Decomposition Products: Thermal decomposition

may result in release of oxides of carbon and nitrogen.

Temperature: Do not expose to temperatures above 200°C

(392°F).

Incompatibility: Avoid exposure to strong oxidizers.

Spill Cleanup and Disposal

Spill Cleanup

Small Spills

Remove sources of ignition.

Clean up spill with wet cloth.

Large Spills

Remove sources of ignition.

Wear protective gear: respirator, rubber gloves, goggles.

Refer to “Safe Handling and Use” in this MSDS.

Clean up spill with scoop, being careful not to generate a lot

of dust.

Waste Disposal

Follow appropriate federal, state and local regulations.

Safe Handling and Use

Respiratory Protection: Not normally required. For large spills,

use NIOSH-approved full face-piece respirator with HEPA
cartridge during cleanup.

Protective Gloves and/or Eye Protection: Not normally

required. For large spills, use rubber gloves and chemical
worker’s goggles during cleanup.

Ventilation: Outside of normal ventilation, not normally

required.

Other Protective Equipment and/or Hygienic Practices: None

Special Precautions

Precautions for Handling or Storage: Protect from high heat.

Avoid making dust.

Other Precautions: None

The information contained in this MSDS is based on data
considered accurate; however, no warranty is expressed or
implied regarding the accuracy of these data or the results to
be obtained from the use thereof. Vendor assumes no
responsibility for injury to vendee or third person party
proximately caused by the product if reasonable safety
procedures are not adhered to as stipulated in the MSDS.
Furthermore, vendor assumes no responsibility for injury to
vendee or third person party proximately caused by
abnormal use of the product even if reasonable safety
procedures are followed. Additionally, vendee assumes the
risk of his use of the product.

Safety Information

Installation Hints

Install your fax unit in a dust-free location away from direct
sunlight.

Do not plug your fax unit into a power source shared by
equipment which produces electrical noise (i.e., air
conditioners, etc.).

Leave electronic adjustments to authorized service personnel.

The LINE terminal connects your fax machine to a standard
telephone line. To avoid damage to your telephone system or
to the fax unit, do not plug your fax machine into anything
other than a standard RJ-11C jack.

Your fax unit is intended to be grounded electrically and is
equipped with a three-wire grounded power cord. For your
safety, do not attempt to defeat your power cord’s grounding
plug.

The power outlet should be located near the equipment and
should be easily accessible.

The TEL port on the back of the unit is only suitable for 2-
wire devices. Not all standard telephones will respond to
incoming ringing when connected to an extension socket.

This equipment may not necessarily provide for the effective
hand-over of a call from a telephone connected to the same
line.

Operation and Maintenance

Use a dry cloth to clean the control panel and the main body
of the unit.

Aside from replacing the toner and image drum cartridge, do
not disassemble or attempt to service this unit yourself. Refer
to a qualified technician for service. See “Service and
Support.”

Disconnect the power cord before trying to remove any
objects that may have fallen into the machine.

When relocating your fax unit, always disconnect the
telephone line before disconnecting the power cord.  Always
reconnect the power cord first.

This unit is not intended to be used in parallel with any other
telephone devices.

If anything happens that indicates that the fax unit is not
working properly or has been damaged, unplug it
immediately.  Follow the instructions in “Service and
Support” to have your fax unit serviced.

These are some of the things to look for:

The power cord or plug is frayed or damaged.

Liquid has been spilled into the printer, or it has been

exposed to water.

The fax unit has been dropped, or the cabinet is damaged.

The fax unit does not function properly when you’re

following the operating instructions.

Summary of Contents for OF5950DL

Page 1: ...lasts so the above limitation may not apply to you OKI DATA SHALL NOT BE RESPONSIBLE OR LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSS ARISING FROM THE USE OF THIS PRODUCT Some sta...

Page 2: ...0 654 3282 1 800 OKI DATA Toll Free in the U S and Canada For quick answers to commonly asked questions the Oki Data Information System Automated Attendant is available 24 hours a day 7 days a week Th...

Page 3: ...ing of Okidata Service Centers Consult our web site at www okidata com In the U S and Canada call 1 800 OKI DATA 1 800 654 3282 In Latin America contact the Latin America Service Coordinator at Oki Da...

Page 4: ...ot applicable Evaporation Rate Butyl Acetate 1 Not applicable Specific Gravity H2 O 1 1 15 Solubility in water Negligible Appearance and odor Black granules no odor Fire and Explosion Hazard Data Flas...

Page 5: ...ur fax unit in a dust free location away from direct sunlight Do not plug your fax unit into a power source shared by equipment which produces electrical noise i e air conditioners etc Leave electroni...

Page 6: ...person who is unconscious If toner is inhaled Take person to an open area for fresh air Seek medical attention If toner gets in the eyes Flush eyes with large quantities of cool water for 15 minutes k...

Page 7: ...the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before in...

Page 8: ...S DANS LES PR SENTES ET D CRITES CI DESSUS AUCUNE GARANTIE EXPLICITE OU IMPLICITE Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D AD QUATION UN BESOIN PARTICULIER NE...

Page 9: ...lez appeler depuis un t l phone proche du t l copieur pour d crire le probl me avec pr cision Nos repr sentants du service la client le ont re u une formation sur tous les produits courants OKI Ils pe...

Page 10: ...ur les poussi res totales ACGIH TLV 10 mg m3 pour les poussi res totales Silice amorphe sublim e moins de 1 en masse CAS 67762 90 7 OSHA PEL 15 mg m3 pour les poussi res totales ACGIH TLV 10 mg m3 pou...

Page 11: ...i re limination des d chets Respectez les r glementations locales en vigueur Pr cautions prendre pour la manutention et l utilisation Protection respiratoire N est normalement pas requise Pour le nett...

Page 12: ...nctionne pas correctement ou qu il a t endommag d branchez le imm diatement et observez les directives de la section Service et support du Guide de l utilisteur pour le faire r parer Voici entre autre...

Page 13: ...s s il y en a sont raccord s ensemble Cette pr caution est particuli rement importante dans les r gions rurales L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recou...

Page 14: ...EN ESTE DOCUMENTO NINGUNA GARANT A EXPRESA O IMPL CITA INCLUYENDO PERO SIN LIMITARSE A GARANT AS DE PROP SITO ESPECIAL TENDR VIGENCIA POR UN PER ODO MAYOR DE UN A O INDICADO ANTERIORMENTE Conformidad...

Page 15: ...de responder las consultas m s frecuentes u obtener asistencia t cnica visite la p gina Web de Oki Data http www okidata com Datos sobre la Seguridad de los Materiales T ner para OKIFAX 5950 P N 4081...

Page 16: ...lasia de la c rnea irritaci n leve de la piel y eccema e irritaci n y bronquitis La exposici n a la inhalaci n a largo plazo puede asociarse con c ncer de pulm n 3 Polipropileno Grupo 3 No clasificabl...

Page 17: ...misma l nea Operaci n y Mantenimiento Utilice un trapo seco para limpiar el panel de control y el chasis principal de la unidad Fuera de cambiar el cartucho del t ner y del tambor de imagen no intente...

Page 18: ...rtos con los dedos Procurar atenci n m dica Para mayor informaci n refi rase a los Datos de Seguridad de los Materiales al final de este manual Declaraciones del Consejo de la Uni n Europea de las Com...

Reviews: