Motor Fan Error
•
Does the low voltage power supply fan run after power-on?
•
No
Is 32V output to the fuse FU502 of the engine board (71K PWB)?
•
No
Is 32V output to the power connector of the engine board (71K PWB)?
32V: Pins 7, 8, 9 and 10
No
Replace the low voltage power unit after checking the cable connection.
▼
•
Yes Replace the engine board.
▼
•
Yes Has the low voltage power supply fan replaced?
Yes End
▼
•
No
Replace the low voltage power supply fan.
▼
•
Yes
Does the engine board fan rotate after power-on?
•
No
Is 32V output to the fuse FU502 of the engine board (71K PWB)?
•
No
Is 32V output to the power connector of the engine board (71K PWB)?
32V: Pins 7, 8, 9 and 10
No
Replace the low voltage power after checking the cable connection.
▼
•
Yes Replace the engine board.
▼
•
Yes Replace the fan of the engine board.
▼
•
Yes
End