6. Procedures for Repairing
Oki Data CONFIDENTIAL
44983601TH Rev.1
6-8 /
Table 6-1 (7/8)
Status
level
Error
code
nnn
LCD (16 digits on the upper level
and 16 digits on the lower level)
(" " shows that nothing is
displayed on the upper level.)
LED
Contents
Ready
Atten
Error
CHECK DATA
REC DATA ERROR
<%DLCODE%>
OFF
ON
It shows that an error occurs during the processing
of received NIC program data to be updated.
1: Size error
2: Check SUM error
3: Printer model No. error
4: Module I/F version error
5: FAT Version error
Error
WAIT A MOMENT
DATA WRITING
OFF
Blinking
In writing the NIC program data to be updated.
Error
POWER OFF/ON
DATA WRITTEN OK
OFF
OFF
It is completed to write the NIC program data to be
updated.
Error
CHECK DATA
DATA WRITE ERROR
<%DLCODE%>
OFF
ON
An error occurs while writing the NIC program data
to be updated.
1: Memory Alloc Error
2: Download File Error
3: Device Free Space Acquisition error
4: Device Inefficient Free Space error
5: File Write error
6: CU-F/W Mismatch error
Error
REBOOTING %CODE%
OFF
ON (OFF) Remove the controller unit.
%CODE%
0: Remove due to other than the following causes.
1: Reboot due to the PJL command.
2: Reboot in accordance with the menu change.
3: Reboot due to the quit operator of the PostScript
language.
4: Reboot from Network Utility (including Web).
Error
SHUTTING DOWN
OFF
OFF
In shutting down.
It is displayed only for printer not supporting Lot6
power spec.
Error
SHUTDOWN
OFF
OFF
The shut down is completed.
It is displayed only for printer not supporting Lot6
power spec.
Error
PLEASE POW OFF
SHUTDOWN COMP
OFF
OFF
The shutdown is completed. Turn off the power.
It is displayed only for printer not supporting Lot6
power spec.
Error
SHUTTING DOWN. PLEASE WAIT
TURN OFF AUTOMATICALLY
OFF
OFF
In shutting down.
It is displayed only for printer supporting Lot6
power spec.
Error
PLEASE TURN OFF
POWER SWITCH
OFF
OFF
Error in shutting down.
It is displayed only for printer supporting Lot6
power spec.
Fatal
POWER OFF/ON
nnn: ERROR
OFF
Blinking
Failures occur in the printer.
The following error name is not displayed. 3 digits
of the error code are entered in nnn displayed in
LCD.
* The lower line is only scrolled for the display.
SERVICE CALL
nnn: ERROR
001
Machine Check Exception
002
DSI Exception (Data read failure)
003
ISI Exception (Instruction read failure)
004
Alignment Exception (Memory access error)
005
Program Exception (Illegal instruction, trap
instruction, privilege violation, and so on)
006
Floating-point Unavailable Exception
007
Instruction Address Breakpoint Exception
(for debugging mode only)
020
CU ROM Hash Check Error (resident or ROM slot 1)
030
CU RAM Check Error (resident)