4. ADJUSTMENT
Oki Data CONFIDENTIAL
44983601TH Rev.1
4-23 /
4.1.3.8 Switching between the Factory mode and the Shipping mode
This self-diagnostic menu item is used to switch between the Factory mode and the Shipping mode.
1. Enter the self-diagnostic mode (level 1) and keep pressing the [MENU ] or [MENU
] key until the following
message is displayed.
FACTORY MODE SET
2. When the [OK] key is pressed, the following message is displayed. Keep pressing the [MENU ] or [MENU
]key
until the target item (refer to the following table) is displayed.
FACTORY MODE
SHIPPING MODE *
3. While the desired item to set is being displayed, press the [OK] key that enables selection of the setting values.
4. While the desired setting value is being displayed, press the [OK] key for long period (3 seconds) that registers
the displayed value in EEPROM. (Returns to the status of step 2.)
5. Repeat steps 2 to 4 as required.
6. Pressing the [ ] key terminates the test. (Returns to the status of step 1.)
Display
Setting value
Function
FACTORY
MODE
FACTORY MODE
Sets the Factory working mode (fuse cut invalid mode).
SHIPPING MODE
Releases the Factory working mode to make the fuse cut function valid.
FUSE INTACT
Note:
******* indicates
INTACT or BLOWN.
K-ID UNIT ******
Checks the fuse status of the K-ID unit.