CW-1RC SERIES CHECKWEIGHER
31
7.2 Frequency Drive Settings
7.2a Standard Drive Parameters
There are two drives that control the case transport roller conveyors. See tables below for
recommended drive settings. Only settings that vary from drive default settings are shown.
For specific information regarding programming of the PowerFlex4M frequency drive refer
to the manufactures’ operation manual, www.rockwellautomation.com / Publication 22F-
UM001C-EN-E
Drive 1 [Scale Conveyor]
No.
Parameter
Parameter Value
Default
Set
P101 Motor NP Volts
480
380
P102 Motor NP Hertz
60
50
P103 Overload
0.9
0.9
P105 Maximum Frequency
60
80
P106 Start Source 1
1
2
P108 Speed Reference 1
1
4
P109 Acceleration Time
10
0.5
P110 Deceleration Time
10
0.5
A410 Preset Frequency 0
0
50
A451 Auto Restart Tries
0
9
A452 Auto Restart Delay
1
0
Drive 2 [Outfeed Case Transport]
No.
Parameter
Parameter Value
Default
Set
P101 Motor NP Volts
480
380
P102 Motor NP Hertz
60
50
P103 Overload
0.9
0.9
P105 Maximum Frequency
60
80
P106 Start Source 1
1
2
P108 Speed Reference 1
1
4
P109 Acceleration Time
10
0.5
P110 Deceleration Time
10
0.5
A410 Preset Frequency 0
0
50
A451 Auto Restart Tries
0
9
A452 Auto Restart Delay
1
0
Summary of Contents for CW1-RC Series
Page 33: ...CW 1RC SERIES CHECKWEIGHER 33 9 COMPONENT DRAWINGS 9 1 CW1 RC...
Page 34: ...CW 1RC SERIES CHECKWEIGHER 34 9 2 Weigh Scale Conveyor Static Powered Roller System...
Page 35: ...CW 1RC SERIES CHECKWEIGHER 35 9 3 Weighing Platform Drop down Scale Conveyor System...
Page 36: ...CW 1RC SERIES CHECKWEIGHER 36 9 4 Electrical Panel Siemens...
Page 37: ...CW 1RC SERIES CHECKWEIGHER 37 9 5 Electrical Operator Controls Pro face...
Page 38: ...CW 1RC SERIES CHECKWEIGHER 38 9 6 Main Air Preparation Stack Pneumatics Norgren...