The position of the mounting of the holes, the distance of the lock in the body of the
locker and the distance of the lock to the strike, as shown in Figure 2-2 and Figure
2-3, must be carried out correctly to avoid problems during closing.
2.3.1
Lock Direction
Lock installation must be carried out with screws in four drilled holes.
Lock assembly depending on if it is right handed or left handed is as follows:
Figure 2-1. Representation of right and left handed locks.
•
Nb: It is important for the customer to send a 3D file of the locker
(parasolid, step) for Ojmar’s technical department to assemble the lock
with the strike and ensure that there are no interference problems between
the different elements of the locker.
2.3.2
Assembly Considerations
The NEXO NLX1 lock is fixed to the locker door with four screws.
•
Recommended screws:
Conglomerate doors: Countersunk coach nut 4.5 x 35 DIN 7996 stainless
steel (depending on the thickness of the door).
Phenolic or metal doors: Countersunk screw M5 x 25 DIN 7985 stainless
steel (depending on the thickness of the door).
•
The maximum tightening torque to apply to the tightening of each screw or
coach nut will be 150 Ncm.
•
The diameter of the central hole must be 23 mm (+1/0 mm). Bevelling the hole
on the inner area of the door is recommended.
ATTENTION: During installation, ensure that the lock does not collide with the
locker body (see Figure 2-2 and Figure 2-3).
The dimensions and location of the anchor points are shown in the following figures
(the dimensions depend on the design of the locker and the type of strike used with
the lock).
Summary of Contents for Nexo NLX1
Page 1: ...E S P INSTRUCTIONS MANUAL VERSION 2 0 NEXO NLX1 SYSTEM...
Page 2: ......
Page 3: ...INSTRUCTIONS MANUAL VERSION 1 0 NEXO NLX1 SYSTEM...
Page 7: ...CONTENTSOJMAR 7 PAGE LEFT BLANK INTENTIONALLY...
Page 39: ...2_MANUAL DE INSTALACI N OJMAR 39 PAGE LEFT BLANK INTENTIONALLY...
Page 57: ...3_PUESTA EN MARCHA OJMAR 57 PAGE LEFT BLANK INTENTIONALLY...
Page 62: ...5_MANUAL DE MANTENIMIENTO 1 2 3 User key master or service 4...
Page 70: ...5_MANUAL DE MANTENIMIENTO...
Page 74: ...5_MANUAL DE MANTENIMIENTO PAGE LEFT BLANK INTENTIONALLY...
Page 150: ...7_API REFERENCE MANUAL options BT group 1 range_from 1 range_to 100...
Page 184: ...7_API REFERENCE MANUAL PAGE LEFT BLANK INTENTIONALLY...
Page 186: ...7_API REFERENCE MANUAL Option b...
Page 187: ...7_API REFERENCE MANUAL OJMAR 187 Option c INSTALLING ONE ROUTER PER 50 LOCKS IS RECOMMENDED...
Page 188: ...7_API REFERENCE MANUAL...