© 2015 OJ Electronics A/S
42
W
at
erline
r
oom Contr
oller -
type W
lC
t
3
2-step mode
Operates an additional output as a boost output.
The selected channel output is the normal floor heating output.
The next channel output is the boost output, which is activated under the
conditions below.
tEmP sets the temperature hysteresis.
(The tolerance before the second output is allowed to activate).
The menu is only shown if 2-step mode is set to ON.
timE sets the time during which temperature is permitted to be too low
before the second output is activated (the output with the next number).
The menu is only shown if 2-step mode is set to ON.
Hot water mode
Operates the channel as a thermostat for a domestic hot water cylinder.
Operates as an ON/OFF regulator, activates the X-OUTPUT and boiler
(but not the UFH pump).
Press the OK (√) button to return to the APP menu.