Commission regulation (EU) No 813/2013 Annex II Table 2
6
8
10
13
17
21
Product information, heat pump space heaters and heat pump combination heaters
Supplier’s name or trademark
Oilon Oilon Oilon Oilon Oilon Oilon
Supplier’s model identifier
ECO 6
07
Cube
6 07
ECO 8
07
Cube
8 07
ECO
10 03
Cube
10 07
ECO
13 07
Cube
13 07
ECO
17 07
ECO
21 07
Air-to-water heat pump
-
-
-
-
-
-
Water-to-water heat pump
Yes
Yes
Yes
Yes
Yes
Yes
Brine-to-water heat pump
Yes
Yes
Yes
Yes
Yes
Yes
Equipped with a supplementary heater
Yes
Yes
Yes
Yes
Yes
Yes
Combination heater
CUBE:
Yes
ECO: -
CUBE:
Yes
ECO: -
CUBE:
Yes
ECO: -
CUBE:
Yes
ECO: -
ECO: - ECO: -
Average temperature application (brine 0/−3 °C, water 47/55 °C), average climate conditions
Rated heat output
P
rated
kW
5
7
9
12
15
19
Seasonal space heating energy efficiency
η
s
%
145
150
157
157
156
159
Bivalent temperature
T
biv
°C
-
-
-
-
-
-
Cycling interval capacity for heating
P
cych
kW
-
-
-
-
-
-
Degradation coefficient
Cdh
–
0.9
0.9
0.9
0.9
0.9
0.9
Declared heating capacity for partial load at an indoor temperature of 20 °C and the outdoor
temperatures and flow temperatures given below (brine 0/−3 °C)
Outdoor temperature −7 °C, flow +52 °C
Pdh
kW
5.2
6.9
9.3
11.8
15.6
19.4
Outdoor tempe2 °C, flow +42 °C
Pdh
kW
5.4
7.2
9.7
12.4
16.4
20.4
Outdoor tempe7 °C, flow +36 °C
Pdh
kW
5.6
7.3
10.0
12.7
16.9
21.0
Outdoor tempe12 °C, flow +30 °C
Pdh
kW
5.7
7.5
10.2
13.0
17.4
21.6
Outdoor temperature −7 °C, flow +55 °C
Pdh
kW
5.1
6.8
9.1
11.7
15.4
19.1
Bivalent temperature
T
biv
°C
-
-
-
-
-
-
Operating limit temperature (outdoor
temperature)
TOL
°C
-
-
-
-
-
-
Declared coefficient of performance for partial load at an indoor temperature of 20 °C and the outdoor
temperatures and flow temperatures given below (brine 0/–3 °C)
Outdoor temperature −7 °C, flow +52 °C
COPd -
2.88
2.96
3.10
3.08
3.10
3.20
Outdoor tempe2 °C, flow +42 °C
COPd -
3.70
3.80
3.97
3.99
3.96
4.05
Outdoor tempe7 °C, flow +36 °C
COPd -
4.29
4.46
4.63
4.65
4.59
4.67
Outdoor tempe12 °C, flow +30 °C
COPd -
4.97
5.34
5.41
5.41
5.34
5.38
Outdoor temperature −7 °C, flow +55 °C
COPd -
2.67
2.75
2.87
2.85
2.88
2.98
Bivalent temperature
T
biv
°C
-
-
-
-
-
-
Operating limit temperature (outdoor
temperature)
TOL
°C
-
-
-
-
-
-
Power consumption
When the unit is in OFF mode
P
OFF
kW
0.00
0.00
0.00
0.00
0.00
0.00
When the thermostat is not requesting heat P
TO
kW
0.01
0.01
0.01
0.01
0.01
0.01
On standby
P
SB
kW
0.01
0.01
0.01
0.01
0.01
0.01
In crankcase heating mode
P
CK
kW
0.00
0.00
0.00
0.00
0.00
0.00
Supplementary heater
Rated heat output
kW
-
-
-
-
-
-
Type of energy input
-
-
-
-
-
-
-
Other items
Capacity control
-
Yes
Yes
Yes
Yes
Yes
Yes
Brine volume flow rate (brine 0/−3 °C, brine
solution: water–ethanol 30 m-%, water +47/
+55 °C)
m3/h
1.0
1.3
1.8
2.3
3.1
3.9
58 (59)