background image

- 2 -

2.

OPERATION

-

1.

Screw Feeding

Each time Automatic Screw Feeder picks up a screw, the count on the SET counter is decremented by one. When the 
last screw of the preset count is picked up, the “COMPLETION” indicator on the counter lights up with beeps.

At the same time, the SET field shows the set count and the SET TOTAL field increments the count by one.

-

2.

 

Number adjustment

When there is a mistake in screw pick-up, and the screw is not counted, you can correct the count. Press the NO COUNT 

button. The SET field and the COMPLETION indicator will flash on the LCD panel. When Automatic Screw Feeder picks 
up the next screw, the SET field and the COMPLETION indicator stop flashing. With this, the count is corrected and the 

normal counting resumes.

LCD

 COUNTER

See the pages below for the configuration and setting of the LCD counter.

Summary of Contents for NJ Series

Page 1: ...ࡍࠋ ᘢ ࡢྡࢆ㦄ࡿഇࢧ ࢺ ࡈὀពୗࡉ ࠋ ᅾࠊᙜ ࡣ ᅜᅜෆ ᨭᗑࡣࡈࡊ ࡲࡏࢇࠋ ྛ 栦ᐈ実ὀព 㸸ࠕwww ohtake root co jp ᩎྖ ⓗᐁ᪉ 㸪 ๓㸪ᩎྖᅾ ᅜἐ ᡤ宻ⓗ ᅜᐁ ࠋ ࠖ ATTENTION www ohtake root co jp is the only web site associated with our company We do not have any branches in China OPTION COUNTER Operation Manual Read these instructions for the proper use of this machine After having read these instructions keep them in a convenient place so you or the ope...

Page 2: ... is an additional feature for the NJ and NSB series Automatic Screw Feeder This manual explains a method of operating and using the counter of Automatic Screw Feeder For information on specifications and adjustment of the automatic screw feeder see the user s manual of the NJ or NSB series Read and save the instructions of this manual and the NJ or NSB series user s manual to achieve the best perf...

Page 3: ...OTAL field increments the count by one 2 2 Number adjustment When there is a mistake in screw pick up and the screw is not counted you can correct the count Press the NO COUNT button The SET field and the COMPLETION indicator will flash on the LCD panel When Automatic Screw Feeder picks up the next screw the SET field and the COMPLETION indicator stop flashing With this the count is corrected and ...

Page 4: ... in this field is incremented by one each time a set is complet ed The screw feeder stops when a screw remains on the stopper and runs when no screw is on the stopper LED indicator This indicator lights up when screws of a present number count are all taken out and goes off when the next screw is taken out This indicator flashes when you press the NO COUNT button when screw feeding is in progress ...

Page 5: ...e value just wait the value stops flashing You can use either of the PRESET buttons to set a value on the flashing digit Changing the sound volume VOLUME SET You can change the magnitude of beeping of the buzzer Press both VOLUME SET buttons NO COUNT and PRESET buttons at the same time for about 4 seconds The COMPLETION indicator flashes Now you can change the volume The beeping volume changes in ...

Page 6: ...p failure NO COUNT When a mistake in pick up action occurs or when the accessed screw is dropped or missed you can cancel the count by mistake Push the NO COUNT button when the feed failure occurs the SET field and the COMPLETION indicator will flash with beeps When the next screw is pick up successfully the SET field and the COMPLETION indicator stop flashing The SET count remains un changed is n...

Page 7: ... 6 ...

Page 8: ...on in whole or in part of this manual without permission is strictly prohibited by copyright law この取扱説明書の一部または全部の無断転載 複製を禁じます Copyright OHTAKE ROOT KOGYO CO LTD 岩手県一関市萩荘字金ヶ崎27 021 0902 Tel 0191 24 3144 Fax 0191 24 3145 27 Kangasaki Hagisyou Ichinoseki Iwate 021 0902 JAPAN Tel 81 191 24 3144 Fax 81 191 24 3145 http www ohtake root co jp as of November 2014 2014 年 11 月現在 27 Kanegasaki Hagisho Ichino...