p. 5
③
Buzzer Volume Setting
Push Buttons A and C together until the display changes to "bu". (see Fig. 6)
Next push Button C only, to increase the volume from "00
~
03".
The displayed buzzer volume number is set and then the display will return
to normal.
FIG 6. Counter display when the buzzer volume is being set. (note "bu")
3
.
2
Remote Mode
・
Operation sequences
Refer to Timing Chart 1(page 9) for details of the operation.
Check the level of electricity, of the feeding operations, on OUT1 & 2.
Check the condition of the feeder on OUT3 & 8.
・
Counter display and operation
Detecting a starting signal resets the counter to (00).
When screws are fed, the counter increases to the set number.
On Remote Mode, you can't clear the counter with the buttons, but can change
the buzzer volume.
FIG 7. Counter display on Remote Mode (note "Pc")
Buzzer volume setting
Feeding number