background image

  -

 

 

注意

 

Caution

 

 

屋外及び高度

1000m

以上の場所での使用はできません。

 

This product is not designed for using outdoor or at highland over 1000 meter altitude. 

振動・衝撃等のある場所では、使用できません。

 

The site of use should be free from stress such as vibration or impacts. 

 

ミストキャッチが納入された時、その梱包状態が損傷していない事を確認してください。

 

Check that the package is not damaged when delivered. 

→梱包の損傷はミストキャッチの寿命低下、異音、故障の原因につながります。

 

Any sign of damages may lead to short life, noise and/or malfunction of the product.

 

周囲温度が

0

℃~

+40

℃で、周囲湿度が

85%RH

以下(非結露)の範囲で必ず使用してください。

 

Working environment should be within the temperature range from 0 to 40 

  with humidity   

less than 85%RH, free from condensation. 

機械や架台等に設置された状態での運搬は絶対にしないでください。

 

また、運搬する場合、衝撃・振動・ムリな荷重は加えないでください。

 

→寿命の低下、異音、破損の原因になります。

 

Never transport MISTCATCH with being mounted on a machine, a mounting stand and the like. 
Shocks, vibrations and excessive load should be avoided during transportation.   
Failure to the above may lead to breakdown, noise problem or shorter lifetime of the product. 

 

排気口付近には精密機器などを配置しないでください。

 

→細かな粒子のオイルミストがかかり、装置の故障の原因になります。

 

Precision equipment should not be arranged near the air outlet to protect them from fine   
particles flown out from MISTCATCH. 

 
 

■各部の名称

  Part names 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

OMC-N215 /-N215H, 
OMC-N225 /-N225H only 

整風デミスタ

  Rectification demister 

モータ

  Motor 

 

点検扉

  Access door 

 

OMC-N215 /-N215H, 
OMC-N225 /-N225H only 

ドレンパイプ

  Drain pipe 

点検扉固定ねじ

 

Access door 

ixation screw 

 

ターボファン

 

Turbo fan

 

 

捕集ユニット

  Collection unit 

 

端子ボックス

 

Terminal box 

 

背面フタ

  Rear cover 

 

ダクトフランジ

  Duct flange 

インナーカバー

  Inner cover 

 

キャッチクリップ

  Draw latch 

 

Summary of Contents for MIST CATCH OMC-N205

Page 1: ...reafter for future reference This brochure contains general instructions for safety handling installation operation and maintenance of MISTCATCH However please understand that they may not cover all p...

Page 2: ...Contents Safety precautions Part names Installation Operation Maintenance Specifications Maintenance parts Warranty...

Page 3: ...ortant matters for safety and therefore have to be observed without fail The marks and the symbols in this manual have the meanings as described below Danger Improper handling may result in serious in...

Page 4: ...elerate rusting of metals or aging of plastics Failure to the above may cause fire breakage or electric leak This product can not be used in an atmosphere containing corrosive substances such as gaseo...

Page 5: ...ndensation Never transport MISTCATCH with being mounted on a machine a mounting stand and the like Shocks vibrations and excessive load should be avoided during transportation Failure to the above may...

Page 6: ...o a oil mist source provide a collision plate or other protective measures against inhaling excessive amount of oil mist and or machining swarf Over inhaling may cause scattering of oil For inhaling e...

Page 7: ...Caution Slinging and craning works should be done only by qualified personnel M8 4 Install the unit using the supplied 4 pieces of M8 anti vibration rubber Pay attention not to tighten the anti vibrat...

Page 8: ...merge the open end of the drain hose in a tank For assuring smooth drainage avoid flattening out the drain hose Faulty drainage may be a cause of scattering of drainage To prevent pooling of oil insid...

Page 9: ...osition the circuit breaker near the MISTCATCH Make sure that the breaker s action is not interrupted by other equipment Do not connect an inverter to the power source Failure to this may lead to brea...

Page 10: ...bow flange mounting surface for sealing Exhaust duct flange M8 Fix the Exhaust duct mounting adapter with the exhaust port of the MISTCATCH using the enclosed M8 bolts Water scatter prevention unit M8...

Page 11: ...M8 countersunk bolts Attach the Filter and the Watertight washer and tighten the Wingnut to fix them OMC N210 N210H OMC N215 N215H OMC N225 N225H For OMC N210 N210H OMC N215 N215H and OMC N225 N225H M...

Page 12: ...us running to the wrong direction will lead to damage or short life of the product Before starting operation ON OFF Turn power on and then off immediately R S Ensure that the direction of motor rotati...

Page 13: ...lection unit and the Rectification demister Clean inside the duct Eliminate the obstacles to exhaust Replace the motor Abnormal vibration Turbo fan is dirty Motor duration expired Clean the Turbo fan...

Page 14: ...open Access door can be detached by pulling it up once opened 4 90 Turn the four locks for Collection unit by 90 degrees to remove and then take out the Collection unit Clean the Collection unit by me...

Page 15: ...of the suction port Remove dirt and foreign matters from the inner surface of suction port Cleaning of Turbo fan Carry out cleaning when excessive dirt was found on the Turbo fan P 14 Detach the Colle...

Page 16: ...n again Attach the Collection unit and close the Access door Connect the power cable to the terminal box Make sure that the motor runs normally Replacement of After filter Loosen the Wingnut to detach...

Page 17: ...7 A 4 0 3 9 3 6 A 7 1 7 1 6 4 A 9 5 9 3 8 4 A Working temperature range 0 40 0 to 40 Working humidity range 85 RH Max 85 RH free from condensation A Noise Characteristic A 66 70 dB 70 74 dB 72 76 dB 7...

Page 18: ...Outline drawing...

Page 19: ......

Page 20: ...MC N225 CU12 OMC N125 TF1 OMC N225 M220 OMC N225H OMC N225 CU11 Warranty 1 This product is covered with a one year warranty from the date of shipment provided that any trouble out of our responsibilit...

Reviews: