■仕様

  Specifications 

●仕様

  Technical data 

型式

 

Model 

OMC-N205 

/-N205H 

OMC-N210 

/-N210H 

OMC-N215 

/-N215H 

OMC-N225 

/-N225H 

最大風量

 

Max. air flow 

4.5/5 m

3

/min 

8/10 m

3

/min

 

14.5/16.5 m

3

/min 

21.5/24.5 m

3

/min 

最大静圧

 

Max. static pressure 

0.59/0.85 kPa 

1.13/1.55 kPa 

1.57/2.17 kPa 

1.88/2.57 kPa 

捕集効率

 

Collection 

efficiency 

OMC-N2** 

99%

以上

(

重量法:2μm以上の粒子径

Min. 99% (For 2

μm or larger particles

 by 

gravimetric method

)

 

OMC-N2**H 

99%

以上

(

重量法:

1

μm以上の粒子径

Min. 99% (For 1

μm or larger particles

 by 

gravimetric method

)

 

定格電圧

 

Rated voltage 

3

  3-phase 

AC 200V/200-220V  50Hz/60Hz 

モータ定格出力

 

Rated motor output 

0.4 kW (2P) 

0.75 kW (2P) 

1.5 kW (2P) 

2.2kW (2P) 

モータ効率

 

Motor efficiency 

76.0/76.0-77.0 % 

81.5/81.1-82.5 % 

IE3/IE3-IE3 

85.8/85.6-86.0 % 

IE3/IE3-IE3 

86.0/86.8-86.9 % 

IE3/IE3-IE3 

定格消費電流

 

Rated current consumption 

1.9/1.7-1.7 A 

4.0/3.9-3.6 A 

7.1/7.1-6.4 A 

9.5/9.3-8.4 A 

使用周囲温度

 

Working temperature range 

0

+40

 

0 to +40 

 

使用周囲湿度

 

Working humidity range 

85%RH

以下(結露なきこと)

 

Max. 85%RH, free from condensation 

騒音

(A

特性

Noise(Characteristic A) 

66/70 dB 

70/74 dB 

72/76 dB 

74/78 dB 

最高吸気温度

 

Max. suction air temp. 

+

80 ℃

 

適合規格

 

Applicable 

standards 

EMC

指令

 

EMC directive 

EMI:EN61000-6-4, 

EMS:EN61000-6-2 

機械指令

 

Machinery 

directive 

EN ISO/12100 

EN60204-1 

Overvoltage category II, Pollution level 3 

環境対応

 

Environmental 

standard

 

RoHS2 

吸入口径

 

Suction port diameter 

φ

98 mm 

φ

123 mm 

φ

148 mm 

φ

198 mm 

塗装色

 

Body color 

粉体塗装:

10GY9/1

相当、

10GY8/4

相当

 

Powder coating: 10GY9/1 equivalent, 10GY8/4 equivalent 

本体質量

 

Weight 

approx. 25.0 kg 

approx. 40.0 kg 

approx. 57.0 kg 

approx. 68.0 kg 

付属品

 

Accessories 

φ32 ドレンホース

  2

 

Drain hose 32mm dia. 2m 

ドレン用ホースバンド

 

Drain hose band 

防振ゴム

 

Anti-vibration rubber 

メンテンナンスシール

 

Maintenance sticker 

1   

取扱説明書

 

Instruction manual 

1   

※1

   

周囲温度

25

℃のときの定格値

 

2   

モータ単体での効率値

 

Remark: 

1    Rated value at the time of the ambient air temperature of 25

Remark: 

2    Efficiency value of the motor unit. 

※1

 

※1

 

2

 

Summary of Contents for MIST CATCH OMC-N205

Page 1: ...reafter for future reference This brochure contains general instructions for safety handling installation operation and maintenance of MISTCATCH However please understand that they may not cover all p...

Page 2: ...Contents Safety precautions Part names Installation Operation Maintenance Specifications Maintenance parts Warranty...

Page 3: ...ortant matters for safety and therefore have to be observed without fail The marks and the symbols in this manual have the meanings as described below Danger Improper handling may result in serious in...

Page 4: ...elerate rusting of metals or aging of plastics Failure to the above may cause fire breakage or electric leak This product can not be used in an atmosphere containing corrosive substances such as gaseo...

Page 5: ...ndensation Never transport MISTCATCH with being mounted on a machine a mounting stand and the like Shocks vibrations and excessive load should be avoided during transportation Failure to the above may...

Page 6: ...o a oil mist source provide a collision plate or other protective measures against inhaling excessive amount of oil mist and or machining swarf Over inhaling may cause scattering of oil For inhaling e...

Page 7: ...Caution Slinging and craning works should be done only by qualified personnel M8 4 Install the unit using the supplied 4 pieces of M8 anti vibration rubber Pay attention not to tighten the anti vibrat...

Page 8: ...merge the open end of the drain hose in a tank For assuring smooth drainage avoid flattening out the drain hose Faulty drainage may be a cause of scattering of drainage To prevent pooling of oil insid...

Page 9: ...osition the circuit breaker near the MISTCATCH Make sure that the breaker s action is not interrupted by other equipment Do not connect an inverter to the power source Failure to this may lead to brea...

Page 10: ...bow flange mounting surface for sealing Exhaust duct flange M8 Fix the Exhaust duct mounting adapter with the exhaust port of the MISTCATCH using the enclosed M8 bolts Water scatter prevention unit M8...

Page 11: ...M8 countersunk bolts Attach the Filter and the Watertight washer and tighten the Wingnut to fix them OMC N210 N210H OMC N215 N215H OMC N225 N225H For OMC N210 N210H OMC N215 N215H and OMC N225 N225H M...

Page 12: ...us running to the wrong direction will lead to damage or short life of the product Before starting operation ON OFF Turn power on and then off immediately R S Ensure that the direction of motor rotati...

Page 13: ...lection unit and the Rectification demister Clean inside the duct Eliminate the obstacles to exhaust Replace the motor Abnormal vibration Turbo fan is dirty Motor duration expired Clean the Turbo fan...

Page 14: ...open Access door can be detached by pulling it up once opened 4 90 Turn the four locks for Collection unit by 90 degrees to remove and then take out the Collection unit Clean the Collection unit by me...

Page 15: ...of the suction port Remove dirt and foreign matters from the inner surface of suction port Cleaning of Turbo fan Carry out cleaning when excessive dirt was found on the Turbo fan P 14 Detach the Colle...

Page 16: ...n again Attach the Collection unit and close the Access door Connect the power cable to the terminal box Make sure that the motor runs normally Replacement of After filter Loosen the Wingnut to detach...

Page 17: ...7 A 4 0 3 9 3 6 A 7 1 7 1 6 4 A 9 5 9 3 8 4 A Working temperature range 0 40 0 to 40 Working humidity range 85 RH Max 85 RH free from condensation A Noise Characteristic A 66 70 dB 70 74 dB 72 76 dB 7...

Page 18: ...Outline drawing...

Page 19: ......

Page 20: ...MC N225 CU12 OMC N125 TF1 OMC N225 M220 OMC N225H OMC N225 CU11 Warranty 1 This product is covered with a one year warranty from the date of shipment provided that any trouble out of our responsibilit...

Reviews: