Summary of Contents for Defender 3000

Page 1: ...DefenderTM 3000 Indicators Instruction Manual i DT33P i DT33XW Manual_DT33 Indicators_V1...

Page 2: ......

Page 3: ...20 3 3 1 Enter the Mode 20 3 3 2 Start Counting 20 3 3 3 Application Settings 20 3 4 CHECK 21 3 4 1 Set Check Limits 21 3 4 2 Positive Check 21 3 4 3 Negative Check 21 3 4 4 Zero Check 21 3 4 5 Appli...

Page 4: ...N 40 5 LEGAL FOR TRADE 41 5 1 SETTINGS 41 5 2 VERIFICATION 41 5 3 SEALING 42 6 MAINTENANCE 44 6 1 CLEANING 44 6 2 TROUBLESHOOTING 45 6 3 SERVICE INFORMATION 45 7 TECHNICAL DATA 46 7 1 SPECIFICATIONS 4...

Page 5: ...nnect the power cord to a compatible grounded electrical outlet Only use a power cord with a rating that exceeds the specifications on the equipment label Only for i DT33P Make sure that the power cor...

Page 6: ...s of load cell connector one supports EasyConnectTM and one does not Therefore the load cell connector varies for different models For some i DT33XW models the position of load cell connector strain r...

Page 7: ...t connector J8 5 RS232 connector J13 11 Security switch connector S1 6 Keyboard connector J4 Figure 1 4 i DT33XW Mainboard Note Mainboard may vary slightly for different regions Item Description Item...

Page 8: ...rminal is on press to power off Units Changes the weighing unit Mode Changes the application mode Menu Enters the user menu Shows a tare value in application modes Menu Function Short Press Yes Accept...

Page 9: ...on Item Description 1 NET symbol 7 Pound Ounce Pound Ounce symbols 2 Center of Zero symbol 8 Kilogram Gram symbols 3 Stable weight symbol 9 Pieces symbol 4 Negative symbol 10 Percent symbol Tonne symb...

Page 10: ...creases or decreases in one grid two grids three grids and four grids The battery level indicator will disappear when the battery is fully charged While operating on battery the battery symbol indicat...

Page 11: ...SHOCK HAZARD REMOVE ALL POWER CONNECTIONS TO THE INDICATOR BEFORE SERVICING OR MAKING INTERNAL CONNECTIONS THE HOUSING SHOULD ONLY BE OPENED BY AUTHORIZED AND QUALIFIED PERSONNEL SUCH AS AN ELECTRICA...

Page 12: ...in some regions Please follow the instruction below for opening the housing and take out the battery Note If your indicator does not contain the lead acid battery but you want to purchase it as an ac...

Page 13: ...led and take it out 5 Remove the five screws circled from the rear housing 6 Open the rear housing 7 Close the rear housing retighten the screws and re install the lead acid battery after finishing in...

Page 14: ...ator to disassemble the bracket 2 Remove the six hex head bolts from the rear housing of the indicator 3 Open the rear housing 4 Close the housing and re install the bolts after finishing internal con...

Page 15: ...horized OHAUS dealer to obtain a load cell cable gland kit P N 30379716 as an accessory 2 3 3 Non EasyConnectTM Indicator To connect a non EasyConnectTM scale base to an i DT33P or an i DT33XW non Eas...

Page 16: ...oad cell cable to the load cell terminal block on the mainboard circled Please refer to the Load Cell Terminal Block section for details of the connections 2 3 3 2 i DT33XW 1 After opening the housing...

Page 17: ...yer of the built in housing 3 Release the load cell connector circled on the bottom of the indicator and then pass the load cell cable through it 4 Connect all the cables on the load cell cable to the...

Page 18: ...Sense SEN terminals The i DT33P and i DT33XW indicators are designed to support both 2mV V and 3mV V load cells from the same circuitry A load cell output rating selection jumper is not required 2 3 3...

Page 19: ...y 3 Release the strain relief for option connector on the bottom of the indicator and remove the plug on it 4 Pass the optional RS232 cable through the connector and attach it to the RS232 terminal bl...

Page 20: ...ing fasteners not supplied that are appropriate for the type of mounting surface The bracket will accommodate up to 6 mm 1 4 diameter screws Locate the mounting holes as shown in Figure 2 7 and 2 8 Fi...

Page 21: ...he tare weight a Long press the Tare button until t wWt is displayed b Release the Tare button and the tare weight will be displayed 3 Add item to the pan or the container The display shows the weight...

Page 22: ...l pieces in the sample are the same Different pieces and weights will result in an inaccurate piece count During the capture process the display shows If the APW is between 0 1d and 1d the display wil...

Page 23: ...values you set are invalid the display will show NO and go back to reset the Under and Over value 8 If the values you set are valid the scale will enter check mode Note Short press the Function button...

Page 24: ...000 Indicators The Check configurations are defined below defaults in Bold Item Available Settings Comments Check CHECK On Off To enable or disable Check Note You cannot disable Check if you are in th...

Page 25: ...he display shows CLr ACC If you need to clear the stored totalization result of the last time press the Yes button and then start totalization If you need to recall the stored totalization result of t...

Page 26: ...enable e Press the Exit button to exit 2 After the Table on option is enabled In automatic totalization mode the scale will automatically print the current weight when it is totalized successfully In...

Page 27: ...Totalization Configurations are defined below defaults in Bold Item Available Settings Comments Totalization total Off Auto Manual To select Totalization method or disable it Note you cannot disable T...

Page 28: ...oz lb oz t End reset BAUd PArItY StOP H SHAKE ALt P ALt t ALt Z End reset ASSIGN Stable mMODE tImME lINkto C SUmM tEmMp End reset BAUd PArItY StOP H SHAKE ALt P ALt t ALt Z ENd reset IP Addr u E r ENd...

Page 29: ...cale capacity the current number is displayed with all digits flashing To revise 1 Press the No button to begin editing 2 The first digit is displayed flashing 3 Press the No button to increase the di...

Page 30: ...se the button and wait for the display to show C A L Press the Yes button 3 The display shows ZErO Press the Yes button 4 0 kg and the calibration unit are flashing on the display With no weight on th...

Page 31: ...d on the scale capacity and unit you set in the setup menu For example 015 000 kg If you do not need to change the calibration point skip to step 7 6 To change the calibration point a Short press the...

Page 32: ...To change the test calibration weight a Short press the No button several times until the desired number appears Note press the Back button can decrease the digit b Short press the Yes button to accep...

Page 33: ...the unit used for calibration kg lb Range rANGE Selects the number of weighing intervals This terminals can be configured to use single or dual interval Each interval can be assigned its own graduati...

Page 34: ...Power On Zero P ZerO Zero the scale at Power On Off disabled ON enabled Power On Unit P UNIt Set the unit that will be displayed at Power On AUtO last unit in use when turned off kg kilograms g grams...

Page 35: ...efaults NO do not reset YES reset Stability StAblE Set the amount reading can vary before the stability symbol turns off 0 5d 0 5 of a scale division 1d 1 scale division 2d 2 scale divisions 5d 5 scal...

Page 36: ...isplay enters sleep mode after the selected time period OFF disabled 1 the display enters sleep mode after 1 minute of no activity 5 the display enters sleep mode after 5 minutes of no activity 10 the...

Page 37: ...a printer or PC Factory default settings are shown in bold 4 6 1 RS232 Menu Enter this menu to define communication parameters Menu Sub Menu Sub Menu in segment Options Options in segment RS232 r S 2...

Page 38: ...for COM1 menu NONE no handshaking ON OFF XON XOFF software handshaking Alternate Print command Alt P Set the alternate command character for Print Settings of A a to Z z are available The default sett...

Page 39: ...menu to factory defaults NO do not reset YES reset Assignment ASSIGN Demand dEmMAN If Demand is selected the sub menu Stable Only will display Set the printing criteria OFF values are printed immediat...

Page 40: ...x D for OH Continuous format OH CON printing occurs continuously lINktO OFF disabled CUst1 print using custom 1 template CUst2 print using custom 2 template SICS SICS OFF disable MT SICS command ON en...

Page 41: ...ize your print template in the software using XXXX format XXXX refers to the index number of each print item Please check the following table for each item s index number Index Number Print Items 5000...

Page 42: ...unction of all buttons If the Menu button has been locked long press the Menu button for 15 seconds until you see UN LOCK Press the Yes button to confirm Item Available Settings bold is the default se...

Page 43: ...n Open the Housing section Note Remove dry batteries for i DT33P if used Remove the lead acid battery if it is included in your i DT33P model Please refer to Open the Housing section i DT33P with Lead...

Page 44: ...5 5 i DT33XW Wire Sealing Figure 5 6 i DT33XW Paper Sealing For the sealing of the scale base when the i DT33P or i DT33XW indicator is connected to an OHAUS Defender 3000 series base boasting EasyCon...

Page 45: ...cell adapter connection the connection between the indicator and the base shall be sealed by using a connector cover P N 30538022 sealing sticker or wire seal i DT33P Figure 5 7 i DT33P Sealing Connec...

Page 46: ...ess steel Indicator housing and rinse with water Dry thoroughly WARNING Electric Shock Hazard Disconnect the equipment from the power supply before cleaning Make sure that no liquid enters the interio...

Page 47: ...ale Error 8 2 Weight reading below Power On Zero limit 1 Add weight to the pan 2 Recalibrate the scale Error 8 3 Weight reading exceeds Overload limit Reduce weight on the pan Error 8 4 Weight reading...

Page 48: ...ic Tonne Modes Weighing Counting Check Totalization Display 45 mm 1 8 in digit height LCD display with 4 color backlight Check undicator 3 color red green yellow bar Keyboard 4 button membrane keyboar...

Page 49: ...lor red green yellow bar Keyboard 4 button membrane keyboard Auto zero tracking Off 0 5 d 1 d or 3 d Load cell excitation voltage 5VDC Load cell drive Up to 6 X 350 ohm Load cell input sensitivity Up...

Page 50: ...4 14 13 13 12 12 11 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13...

Page 51: ...2012 UK Electromagnetic Compatibility Regulations 2016 Electrical Equipment Safety Regulations 2016 and Non Automatic Weighing Instruments Regulations 2016 The UK Declaration of Conformity is availabl...

Page 52: ...as been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer...

Page 53: ...ix digits no decimal point or sign Insignificant leading zeroes are replaced with spaces 4 Tare weight Six digits of tare weight data No decimal point in field 5 ASCII Carriage Return CR character 0D...

Page 54: ...1 and 0 Weight Description 2 1 0 0 0 0 lb or kg selected by Status Byte B bit 4 0 0 1 grams g 0 1 0 metric tons t 0 1 1 ounces oz 1 0 0 not used 1 0 1 not used 1 1 1 tons ton 1 1 1 no units Bit 3 Pri...

Page 55: ...nter P101 Print out stable weight value P102 Print out current weight value immediately SIRU Send weight value in the current unit immediately and repeat SIU Send weight value in the current unit imme...

Page 56: ...pplication ID Example M 0 Please check the following table 9 2 for the ID of each application Inquiry M PSN Print indicator s serial number CU Set inquiry Under Limit only in Check mode Set CU under v...

Page 57: ...ned Space Stability Space T N G PT Right aligned Space Application Status Right aligned Term Length 11 1 5 1 1 1 2 1 6 2 Note Application Status is fixed to 6 characters The printed status will be Und...

Page 58: ...has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other th...

Page 59: ......

Page 60: ...h offices worldwide Con oficinas en todo el mundo Avec des bureaux partoutdans le monde MitB rosweltweit Con uffici in tuttoilmondo www ohaus com 30696592 P N 30696592A 2021 Ohaus Corporation all righ...