CHECKING FUNCTIONING
The appliance contains the instructions necessary for use.
Check the appliances for gas leaks.
Check the lighting and flame of the main burner.
We urge the user to follow the instructions when using the appliance.
MAINTENANCE
With prolonged use of the appliance, it is essential to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service. Maintenance must be done only
by specialized personnel, observing the norms in force and our indications.
SPARE PARTS
Coup de feu:
It is possible to substitute the spark plug cock, thermocouple and burner after having removed the front panel.
Open rings:
The cocks can be changed by removing the front panel; to change the thermocouples and burners you have to
remove the rungs and trays.
Gas oven:
the gas-cock, timer, thermocouples, burners and ignition plugs can be changed by accessing them inside the oven
and/or by removing the bottom oven panel or control panel.
25
Officine Gullo
USER MANUAL
INSTRUCTIONS FOR USE
Attention! The appliance must only be used under surveillance.
LIGHTING AND ADJUSTING THE BURNERS
On the front panel, above each knob, there is a symbol which indicates to which burner
the knob corresponds.
To light, turn the knob to the left from position “0” to the
symbol (see figure); keep
it pushed down and press the button with the
symbol until the gas lights.
The knob must be kept pushed down for a few seconds and then released. The flame
may go out, in which case it is necessary to repeat the procedure. By turning to the
position, the burner is brought to the minimum. To put out the burner, turn the knob back
into the “0” position.
LIGHTING AND ADJUSTING THE COUP DE FEU
On the front panel, above each knob, the burner it corresponds to is indicated by the
index.
To light the pilot flame, turn the knob to the left from position “0” to the
symbol
(see figure); keep it pushed down and press the button with the
symbol until the gas
lights. Keep the knob pressed a few second and then let it go.
If the flame goes out you have to repeat the procedure.
By turning the knob round to the position the burner is at maximum.
By turning the knob round to the position the burner is at minimum. To switch off,
move the knob back into position " 0".
Summary of Contents for GGS8P
Page 2: ......
Page 4: ...Officine Gullo 4 E Electrical Connection G Gas Connection INSTALLATION MANUAL Fig A 1 GES8P ...
Page 5: ...5 Officine Gullo E Electrical Connection G Gas Connection Fig A 2 GES12P ...
Page 6: ...Officine Gullo 6 E Electrical Connection G Gas Connection Fig A 3 GEPS8P ...
Page 7: ...7 Officine Gullo E Electrical Connection G Gas Connection Fig A 4 GEPS12P ...
Page 8: ...Officine Gullo 8 E Electrical Connection G Gas Connection Fig A 5 GGS8P ...
Page 9: ...9 Officine Gullo E Electrical Connection G Gas Connection Fig A 6 GGS12P ...
Page 10: ...Officine Gullo 10 E Electrical Connection G Gas Connection Fig A 7 GGPS8P ...
Page 11: ...11 Officine Gullo E Electrical Connection G Gas Connection Fig A 8 GGPS12P ...
Page 14: ...Officine Gullo 14 Fig G Coup de feu 1 Injector 2 Pilot ...
Page 30: ...Officine Gullo 30 ...
Page 31: ...31 Officine Gullo ...