20 English
S1.9
LOCKING THE MENU
This setting limits the access to parameter groups
in the menu.
0 - no lock
1 - S1
2 - P1, P2 and S1
S1.10
LOCKING KEYS
This setting locks key functionality.
Operation of locking keys is described in the chapter
»Locking keys«.
0 - no lock
1 - operation type,
2 - same as 1 and
functions,
3 - same as 2 and desi-
red temp.,
4 - same as 3 and info
browsing and settings.
S1.11
MINIMUM SETTING OF TEMPERATURE
This setting determines the minimum possible
setting of room temperature.
4 ÷ 40 °C (
6
)
S1.12
MAXIMUM SETTING OF TEMPERATURE
This setting determines the maximum possible
setting of room temperature.
4 ÷ 40 °C (
30
)
S1.13
PERIOD OF IGNORING ROOM TEMPERATURE
Used with the »fireplace« function. Operation of fire
-
place function is described in the chapter »Fireplace
Function«
1 ÷ 12 ur (
5
)
S1.14
ALTITUTE FOR WEATHER FORECAST
This setting enters the altitude of the room unit. This
improves the weather forecast.
0 ÷ 1999 m (
300
)
LOCKING SETTINGS
By locking settings, access to individual parameter groups is disabled.
Only unlocked parameter groups are visible. Locked settings can be
temporarily unlocked by pressing the key for 10 seconds, when being
in the last unlocked setting group.
Parameter S1.9 determines the lockings:
S1.9=0 - no lock,
S1.9=1
- group S1 is locked,
S1.9=2 - groups P1, P2 and S1 are locked.