Operating levels
Settings
9
Settings
Parameter
Designation
Adjustment range
Factory default
/$1*8$*(
Parameter designation language
D GB F NL E I
German
7,0(
Time
00:00-24:00
10:00
'$<
Day of week
1-7
1 (Monday)
$'$352207
Room sensor adaptation
-5°C - +5°C
0°C
'(652207(03
Current desired room temperature (including correction)
Display only
$11281&(
Desired room temperature on standard display
On/Off
Off
%8517,0(
Display of burner operating time in hours
Display only
%85167$57
Display of burner starts
Display only
237,0,=$7
Display of last time advance required
Setting of maximum time advance
0 (= Off) - 3
hours
2 hours
&RQWURO,
Control I/0 or Proportional mode
Control I/0
&RQWURO,
:
+\VWHUHVLV
Hysteresis for ON/OFF control
'HOD\
Delay for relay state
0.1 K - 2.0 K
0-30 min
0.4 K
0 min
3URSRUWLRQDO
:
+\VWHUHVLV
Dead band for proportional mode
6DPSOLQJWLPH
Cycle time for proportional mode
0 K – 2.0 K
0-30 min
0 K
10 min
&RQWURO2II
:
The relais switches only time dependent.
0/1
0
+HDWLQJ
Heating or cooling mode
H, K
Heating
7HOHSKRQHL
Telephone switch or window contact
T, F
Telephone I-0
5HVHW
Load factory default:
1) for heating program 1 or
2) for heating program 2 or
3) for all temperatures and all settings of this list (apart from language, time and date)
4) or for all values.