OEG Como Operating And Installation Instructions Download Page 6

Settings

Operation

6

Settings

Changing the settings

Opening the hinged control panel
cover causes the operation-control
module to switch automatically to In-
formation and Programming mode.
The operating controls are assigned a
new significance (which can be seen
from the printed designations which will
now appear beneath the keys).

All entries can be made on the basis
of the same principle
1.  Open the hinged cover on the front

of the controller; the controller
switches to INFO mode. The three
keys are then assigned the function
printed on the inside of the hinged
cover.

2.  Choose the required parameter of

the current level or another level
with keys +/-.

3.  Press the Programming key 

.

4.  If you press key 

 and have se-

lected a lower operating level
-> continue at Point 2!

5.  If you press key 

 and have se-

lected a setting, the controller
changes to Programming mode

(Programming indicator 

 

).

6.  The parameter value can be

changed with keys 

 or 

.

7. Press key 

 again; this saves the

new value.

8.  If you close the hinged cover before

pressing key 

, this quits Pro-

gramming mode. The controller
switches to the standard display
(boiler temperature and time). The
changed value is not saved.

!

You can branch up to the next oper-
ating level by pressing key 

 and

selecting the "RETURN" function.

Designation of the entry or of

the operating level.

Entry

Programming indicator

(Warning triangle 

 

)

Programming key

E

 key: Next setting /

increment setting

F

 key: Previous setting /

decrement setting

RESET switch

Desired room temperature

correction

A

B C

E

G

H

F

D

Summary of Contents for Como

Page 1: ...Room controller Como Operating and Installation Instructions Please follow the safety information and read through these Instructions carefully before placing the system into operation...

Page 2: ...mmis sioned serviced and repaired profes sionally this will render the manufac turer s warranty null and void Declaration of conformity Como corresponds to the requirements of the relevant guidelines...

Page 3: ...e the time and the day of the week in order to op erate the controller 1 Open the hinged front panel b 2 Press key 3 Select the language with keys 4 Press key twice 5 Set the time with keys 6 Press ke...

Page 4: ...is pressed the heating circuit switches to Reduced mode for 1 further hour In Reduced mode ECO Each time key is pressed Re duced mode is prolonged by one hour Pressing the Party key shortens the set...

Page 5: ...st protection Automatic 1 Auto matic 2 Heating mode Reduced night mode A C D E F H I J K M L B The standard display shows the following information A It is Saturday B The time is 12 47 C The current r...

Page 6: ...he Programming key 4 If you press key and have se lected a lower operating level continue at Point 2 5 If you press key and have se lected a setting the controller changes to Programming mode Programm...

Page 7: ...acti vate a switching time with the Pro gramming key Warning triangle and then save the value by pressing the Programming key again All switching values in the block are overwritten by the switch ing...

Page 8: ...ith the delay setting PROPORTIONAL control Heating mode is switched on for a per centage 50 of the adjustable cycle time as a function of the deviation be tween the measured and desired tem perature o...

Page 9: ...time advance required Setting of maximum time advance 0 Off 3 hours 2 hours RQWURO Control I 0 or Proportional mode Control I 0 RQWURO VWHUHVLV Hysteresis for ON OFF control HOD Delay for relay state...

Page 10: ...he Holiday pro gram starts on the day of entry S HOLIDAY 00 with S HOLIDAY 05 in 5 days If the holiday period is entered after 12 00 hours the pro gram starts on the next day at 12 00 hours It thus al...

Page 11: ...re engage the top section at the upper edge of the socket and swivel it back onto the base d Press on until the top section en gages in position For the fitter Installation A Hole for fastenings scre...

Page 12: ...closure to EN 60529 IP 40 Safety class to EN 60730 II totally insulated Power reserve of the timer battery change 2 min Permitted ambient temperature during operation 0 to 50 C Permitted ambient tempe...