. As the batteries are non-hazardous, disposal is with your normal 

rubbish. We recommend with temperatures greater than 0ºC to use the Energizer Max E91 with 
PowerSeal Technology batteries as these have been tested in our Xtreem products to give the best 
life and are least likely to leak. At 0ºC the battery life is reduced to half of its calculated life and it 
further reduces to 1/8

th

 of its life at -20ºC. 

For temperatures below 0ºC we recommend Energizer Lithium L91 batteries and these will have a 
life of greater than 2 years even at -20ºC.  Replace the batteries in the logger in the indicated 
orientation in the battery holder. ( Note the unit will not be damaged if the batteries are inserted 
incorrectly ). Before replacing the cap check the O-Ring seal is present, clean and free from dirt. If 
required apply some silicon grease ( available fro

www.OdysseyDataRecoding.com

 ). Replace the 

cap and tighten by hand. Do Not use any tools to tighten the cap. 

If the logger is not to be used for more than a year, then remove the batteries to prevent any chance 
of leaking.  

Specifications

Description

Radio

NRF52832 Bluetooth SOC from Nordic Semiconductor

Frequencies

2402 – 2480MHz

Modulation

GFSK

Bandwidth

1MHz

Output Power

+4.0dBm max

Antenna

Ceramic Chip with 0.5dB gain.Return Loss -9.5dB
UFL ( external )

Operating Temperature

-20 to 55ºC (standard)

Relative Hunidity

0% to 100%

Water Proof

IP67 (30mins submersion to 1m), IP68 on request

Dimensions

46mm Diameter,  160mm  Length
Sensor Length 1m

DATAFLOW SYSTEMS LTD

Page 9

www.Odysseydatarecording.com

 

            V 03/21

Summary of Contents for Xtreem

Page 1: ...Odyssey Xtreem Single Soil Moisture Logger User Manual Xtreem Single Soil Moisture Logger User Diagram DATAFLOW SYSTEMS LTD Page 1 www Odysseydatarecording com V 03 21...

Page 2: ...Configuration 4 Calibration 4 Transfer Configuration to Logger 5 Soil Types 5 Volumetric Measurement 6 Calculations 6 Collecting Data 7 Viewing Data 7 ICON pop up 7 Selected Logger Box 7 Latest Infor...

Page 3: ...sor cable must be plugged into the logger The connector is keyed so once this is lined up push the connector in as far as it goes and then rotate the top of the connector until it locks into place The...

Page 4: ...oad the full Odyssey Xpert user manual from Xpert web portal Logger Configuration 1 Select the Logger Config Tab Enter a Logger Name that will be used to Identify the Logger from now on The serial num...

Page 5: ...s than 10 minutes through the tablet phone running the Xtract Application To apply this immediately press the SERVER SYNC button in the Settings screen Once the button has been pressed the time below...

Page 6: ...calibration page do not affect the factory calibration of the logger just the displayed and exported data Choose the Custom Soil type from the drop down box and enter the drypoint value and field capa...

Page 7: ...then select a logger to be configured An Icon for the logger will display on the Map Click on the icon It may be necessary to Zoom the Map out to find the Logger ICON pop up This pop up shows brief da...

Page 8: ...rding at least 60000 records The number of recording days before the memory is full can be calculated using the following formulae If continuous logging is enabled the oldest will overwritten first If...

Page 9: ...er Note the unit will not be damaged if the batteries are inserted incorrectly Before replacing the cap check the O Ring seal is present clean and free from dirt If required apply some silicon grease...

Page 10: ...diation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body Japan MIC The Xtree...

Reviews: