background image

General Operation

14

Multi-Stage Charging Overview
Stage 1 - Unit Self Test:

 During this stage the ODYSSEY

®

 Battery Portable Charger is

checking the connections, polarity and that the battery is good and will then proceed to

Stage 2 analyzing.

Stage 2 - Analyzing: 

The charger is checking to make sure the battery is capable of being

charged. Upon successful completion of both stage 1 and 2, the “System Check OK” indicator

will illuminate green followed by Stage 3 Charging.

Stage 3 - Charging: 

During this mode the “Charging” indicator will be red. The charger will

use all of its available charging amps (as controlled by temperature) until the battery voltage

is raised to 14.7VDC.

Stage 4 - Conditioning: 

During this mode the “Conditioning” status indicator will be amber.

Batteries will be held at 14.7 VDC for several hours to condition batteries and fully charge

a battery. Upon completion the charger will go into its Auto Maintain (Energy Saver Mode).

Stage 5 - Auto Maintain (Energy Saver Mode): 

During this mode the blue “Power” and green

“Auto Maintain” LEDs will be on indicating Stage 3 Charging and Stage 4 Conditioning are

completed. At this time the charger will initiate its Auto Maintain (Energy Saver Mode) which

will monitor and Auto Maintain batteries only when needed to maintain a full state of charge.

Stage 6 - Storage Recondition Mode:  

During this mode the “Storage Recondition Mode”

green indicator will illuminate with a slow fade in and out pulse. This indicates that while

your batteries are in storage the charger will automatically recondition the battery for up to

3 hours once a month extending battery life and maximizing the battery power performance.

14

13

12

11

Volts

Charging

Conditioning

Auto Maintain

Storage Recondition Mode

Average Voltage

Analyzing

Unit Self Test

General Operation

13

ODYSSEY

®

 Battery Portable Charger LED Status Center - Operation and Display

The ODYSSEY

®

 Portable Charger includes seven LEDs for operation status and one

battery bank trouble LED depending.
1. Blue AC Power LED

Illuminates when AC power is present

2. Green System Check OK LED

After connecting the charger according to the instruction manual followed by applying

AC power to the charger, the charger will self test all battery connections and the battery

to make sure it is above 2.5 VDC and can accept a charge.
If all tests pass, the “System Check OK” indicator will illuminate green, providing positive

confirmation followed by the charging process. This may take up to two minutes.

3. Charge Mode LEDs - Each LED will sequentially illuminate after the previous mode 

is completed.

Self Test: 

Blue LED illuminates confirming self test is in process of 

testing connections, polarity and that the battery connected 

is over 2.5 VDC and is able to accept a charge.

Charging: 

Red LED will be solid red during charging.

Conditioning: 

Amber LED illuminates during conditioning mode.

Auto Maintain:

Green LED illuminates when batteries are fully charged and 

(Energy Saver Mode) 

being monitored to automatically maintain your fully charged

battery until you are ready to use it.

Storage Recondition: 

While the Auto Maintain LED remains on. This Green LED fades

in and out when performing a once a month storage recondition

mode to your battery.

4. Battery Trouble Status

Red LED will illuminate indicating a wiring problem or fault with battery connected to 

the portable charger. See page 21 for further details.

Charge Mode

Self Test

Conditioning

Auto Maintain

Charging

Storage Recondition

System Check OK

AC Power

0

%

100

%

Charge Monitor

When illuminated, check one of the following:

- Reverse polarity
- Poor connections
- Battery too low

to charge

Battery Trouble Status

See help section in manual for assistance.

Summary of Contents for OBC-12A

Page 1: ...FCC Class A Part 15 CEC Listed ODYSSEY Battery12AmpPortableCharger OBC 12A 12 12 120VAC 10 6 9 25 x 11 25 x 3 88 ODYSSEY Battery20AmpPortableCharger OBC 20A 12 20 120VAC 10 6 9 25 x 13 75 x 3 88 Model...

Page 2: ...being charged correctly The Self Test is automatic and will take place every time the unit is plugged into a 110VAC outlet The Self Test may take up to two minutes to complete During the Self Test th...

Page 3: ...tains important safety and operating instructions for the ODYSSEY Battery Portable Charger WARNING To reduce the risk of injury to user or property the user must read and understand the instruction ma...

Page 4: ...all EnerSys Energy Products Inc at 1 660 429 2165 between 8 30 am 5 00 pm Central Standard Time Unauthorized attempts to service repair or modify may result in a risk of electrical shock fire or explo...

Page 5: ...parts Place away from the battery using the length of the DC cables l Consult vehicle owner s manual Personal Precautions 5 18 PREPARINGTOCHARGEA BATTERY CAUTION a When it is necessary to remove a bat...

Page 6: ...njury to persons c Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post d Identify if you have a negative or positive grounded vehicle...

Page 7: ...may be under 2 5 volts a red LED fault indicator will turn on and the System Check OK will not illuminate Equally a successful self test will result in a positive System Check OK LED illuminating foll...

Page 8: ...e Batteries AGM Type Batteries Flooded AGM AGM Type Batteries AGM Type Batteries Flooded AGM Flooded Type Batteries Flooded Type Batteries 220 CCA through 330 CCA Flooded AGM For non cycling applicati...

Page 9: ...alyzing Unit Self Test General Operation 13 ODYSSEY Battery Portable Charger LED Status Center Operation and Display The ODYSSEY Portable Charger includes seven LEDs for operation status and one batte...

Page 10: ...h the battery f There will be up to a two minute check process to make sure connections and the battery are correct then the charger will start the charge When the charge cycle starts the Charge Monit...

Page 11: ...Cable WARNING Read and Follow all INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE SERIOUS INJURY DAMAGE OR EXPLOSION ALWAYS WEAR SAFETY GLASSES Read and follow all General and Personal Safety P...

Page 12: ...elf test This feature is to provide a rough indication of the charging process so at a glance you can see what charge level the battery is at and what remains to complete the charge process 100 First...

Page 13: ...hechargerisnotundersizedforthebattery you are charging With the charger on using a digital volt meter read DC voltage across the battery If the DC voltage reading increases over time this will serve a...

Page 14: ...chases contact Manufacturer at 800 964 2837 You will need to provide the order number original date of purchase serial number and date stamp from top of the charger At the sole discretion of Manufactu...

Reviews: