background image

General Overview

10

The ODYSSEY

® 

Battery Portable Charger Series is our newest line of digital fully automatic

12 volt portable battery chargers, designed to fully charge and enhance the performance

and extend the life of ODYSSEY

®

 and other quality brands of 12 volt flooded and AGM

(Absorbed Glass Mat) lead acid batteries.
Whether a professional shop user or the enthusiast doing a charger-to-battery match up,

our professional grade design delivers performance and quality. Our all digital power

charging platform is packaged in our most ruggedized and weatherproof housing for use

in all conditions. Designed to last, our Portable Chargers are fanless insuring a longer

lifetime of use without the need to replace failing or failed fans as seen in other competitive

products.
Featuring an intuitive LED user interface display, the ODYSSEY

®

 

Battery Portable Charger

sports a battery charge monitor providing an at a glance indication of charge level. In

addition, each model includes power-on self testing to confirm connections are correct

and that the battery can accept a charge, and that it is not below 2.5 volts.
In the event of a bad connection or a battery that is not able to accept a charge and may

be under 2.5 volts, a red LED fault indicator will turn on and the “System Check OK” will

not illuminate. Equally a successful self test will result in a positive “System Check OK”

LED illuminating followed by the charge mode operation.

Out-of-Vehicle Battery Charging Safety Precautions

9

22.

 FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE. A SPARK NEAR

  BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK 

  NEAR A BATTERY:

  CAUTION

a. Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has a larger 

diameter than the NEGATIVE (NEG, N, –) post.

b. Attach at least a 60 cm 6-gauge (awg) insulated battery cable to a negative

(NEG, N, –) battery post.

c. Connect the RED POSITIVE (POS, P, +) cable clamp or ring terminal to the POSITIVE

(POS, P, +) post of battery.

d. Position yourself and free end of cable as far away from the battery as possible - then 

connect the BLACK NEGATIVE (NEG, N, –) charger cable clamp or ring terminal to the 

free end of cable.

e. Do not face battery directly when making final connection.
f. Connect charger AC supply cord to a properly grounded fault protected electric outlet.
g. When disconnecting charger, always do so in reverse sequence of connecting procedure

and break first connection while standing as far away from the battery as practical.

h. A marine (boat) battery must be removed and charged on shore. To charge it on board 

requires equipment specially designed for marine use.

Summary of Contents for OBC-12A

Page 1: ...FCC Class A Part 15 CEC Listed ODYSSEY Battery12AmpPortableCharger OBC 12A 12 12 120VAC 10 6 9 25 x 11 25 x 3 88 ODYSSEY Battery20AmpPortableCharger OBC 20A 12 20 120VAC 10 6 9 25 x 13 75 x 3 88 Model...

Page 2: ...being charged correctly The Self Test is automatic and will take place every time the unit is plugged into a 110VAC outlet The Self Test may take up to two minutes to complete During the Self Test th...

Page 3: ...tains important safety and operating instructions for the ODYSSEY Battery Portable Charger WARNING To reduce the risk of injury to user or property the user must read and understand the instruction ma...

Page 4: ...all EnerSys Energy Products Inc at 1 660 429 2165 between 8 30 am 5 00 pm Central Standard Time Unauthorized attempts to service repair or modify may result in a risk of electrical shock fire or explo...

Page 5: ...parts Place away from the battery using the length of the DC cables l Consult vehicle owner s manual Personal Precautions 5 18 PREPARINGTOCHARGEA BATTERY CAUTION a When it is necessary to remove a bat...

Page 6: ...njury to persons c Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post d Identify if you have a negative or positive grounded vehicle...

Page 7: ...may be under 2 5 volts a red LED fault indicator will turn on and the System Check OK will not illuminate Equally a successful self test will result in a positive System Check OK LED illuminating foll...

Page 8: ...e Batteries AGM Type Batteries Flooded AGM AGM Type Batteries AGM Type Batteries Flooded AGM Flooded Type Batteries Flooded Type Batteries 220 CCA through 330 CCA Flooded AGM For non cycling applicati...

Page 9: ...alyzing Unit Self Test General Operation 13 ODYSSEY Battery Portable Charger LED Status Center Operation and Display The ODYSSEY Portable Charger includes seven LEDs for operation status and one batte...

Page 10: ...h the battery f There will be up to a two minute check process to make sure connections and the battery are correct then the charger will start the charge When the charge cycle starts the Charge Monit...

Page 11: ...Cable WARNING Read and Follow all INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE SERIOUS INJURY DAMAGE OR EXPLOSION ALWAYS WEAR SAFETY GLASSES Read and follow all General and Personal Safety P...

Page 12: ...elf test This feature is to provide a rough indication of the charging process so at a glance you can see what charge level the battery is at and what remains to complete the charge process 100 First...

Page 13: ...hechargerisnotundersizedforthebattery you are charging With the charger on using a digital volt meter read DC voltage across the battery If the DC voltage reading increases over time this will serve a...

Page 14: ...chases contact Manufacturer at 800 964 2837 You will need to provide the order number original date of purchase serial number and date stamp from top of the charger At the sole discretion of Manufactu...