Odyssey OBC-12A Owner'S Manual Download Page 6

Charger Location & DC Connection

7

19.

 CHARGER LOCATION

    CAUTION

a. Locate charger as far away from battery as DC cables permit.
b. Never place a charger directly above a battery being charged; gases or fluids from 

battery will corrode and damage charger.

c. Do not operate charger in an enclosed area or in an area with restricted ventilation in

any way.

d. Never allow battery acid to drip on charger when reading electrolyte specific gravity

or filling a battery.

e. Do not set a battery on top of charger.
f.  Do not install on or over combustible surfaces.
20.

 DC CONNECTION PRECAUTIONS

   

CAUTION

a. Connect and disconnect DC output clips only after setting any charger switches to

"off" position and removing AC cord from electric outlet. Never allow clips to touch

each other.

b. Attach charging clamps to battery and chassis described in section 21 and 22.

In-Vehicle Battery Charging Safety Precautions

8

21.

 FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN A VEHICLE. A SPARK

 NEAR BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A 

 SPARK NEAR A BATTERY:
 CAUTION

a. Position AC and DC cords to reduce risk of damage by hood, door or moving engine parts.
b. Stay clear of fan blades, belts, pulleys and other parts that can cause injury to 

persons.

c. Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has a 

larger diameter than the NEGATIVE (NEG, N, –) post.

d. Identify if you have a negative or positive grounded vehicle. This can be done 

by identifying which battery post NEGATIVE (NEG, N, –) OR POSITIVE (POS, P, +) 

is connected to the chassis.

e. For a negative grounded vehicle: connect the RED POSITIVE (POS, P, +) cable 

clamp or ring terminal first to the positive post of the battery, then connect the 

BLACK NEGATIVE (NEG, N, –) cable clamp or ring terminal to the vehicle’s 

chassis. Do not connect the black negative (NEG, N, –) cable clamp to metal fuel

lines or anywhere in proximity of the carburetor or the battery itself. Connect to 

a heavy gauge metal part of the frame or engine block.

f. For a positive grounded vehicle: connect the BLACK NEGATIVE (NEG, N, –) cable 

clamp or ring terminal first to the negative post of the battery, then connect the 

RED POSITIVE (POS, P, +) cable clamp or ring terminal to the vehicle’s chassis. Do 

not connect the red positive (POS, P, +) cable clamp to metal fuel lines or anywhere 

in proximity of the carburetor or the battery itself. Connect to a heavy gauge metal

part of the frame or engine block.

g. Connect charger AC supply cord to a properly grounded fault protected electric outlet.
h. When charging is completed always disconnect AC power, remove clip from vehicle 

chassis and then remove clip from battery terminal.

Summary of Contents for OBC-12A

Page 1: ...FCC Class A Part 15 CEC Listed ODYSSEY Battery12AmpPortableCharger OBC 12A 12 12 120VAC 10 6 9 25 x 11 25 x 3 88 ODYSSEY Battery20AmpPortableCharger OBC 20A 12 20 120VAC 10 6 9 25 x 13 75 x 3 88 Model...

Page 2: ...being charged correctly The Self Test is automatic and will take place every time the unit is plugged into a 110VAC outlet The Self Test may take up to two minutes to complete During the Self Test th...

Page 3: ...tains important safety and operating instructions for the ODYSSEY Battery Portable Charger WARNING To reduce the risk of injury to user or property the user must read and understand the instruction ma...

Page 4: ...all EnerSys Energy Products Inc at 1 660 429 2165 between 8 30 am 5 00 pm Central Standard Time Unauthorized attempts to service repair or modify may result in a risk of electrical shock fire or explo...

Page 5: ...parts Place away from the battery using the length of the DC cables l Consult vehicle owner s manual Personal Precautions 5 18 PREPARINGTOCHARGEA BATTERY CAUTION a When it is necessary to remove a bat...

Page 6: ...njury to persons c Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post d Identify if you have a negative or positive grounded vehicle...

Page 7: ...may be under 2 5 volts a red LED fault indicator will turn on and the System Check OK will not illuminate Equally a successful self test will result in a positive System Check OK LED illuminating foll...

Page 8: ...e Batteries AGM Type Batteries Flooded AGM AGM Type Batteries AGM Type Batteries Flooded AGM Flooded Type Batteries Flooded Type Batteries 220 CCA through 330 CCA Flooded AGM For non cycling applicati...

Page 9: ...alyzing Unit Self Test General Operation 13 ODYSSEY Battery Portable Charger LED Status Center Operation and Display The ODYSSEY Portable Charger includes seven LEDs for operation status and one batte...

Page 10: ...h the battery f There will be up to a two minute check process to make sure connections and the battery are correct then the charger will start the charge When the charge cycle starts the Charge Monit...

Page 11: ...Cable WARNING Read and Follow all INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE SERIOUS INJURY DAMAGE OR EXPLOSION ALWAYS WEAR SAFETY GLASSES Read and follow all General and Personal Safety P...

Page 12: ...elf test This feature is to provide a rough indication of the charging process so at a glance you can see what charge level the battery is at and what remains to complete the charge process 100 First...

Page 13: ...hechargerisnotundersizedforthebattery you are charging With the charger on using a digital volt meter read DC voltage across the battery If the DC voltage reading increases over time this will serve a...

Page 14: ...chases contact Manufacturer at 800 964 2837 You will need to provide the order number original date of purchase serial number and date stamp from top of the charger At the sole discretion of Manufactu...

Reviews: