background image

                                                                                                                                                   LA715 
 

 

5  

 

 

 

 

 

 

 

 

User ManualP2640300  

3 – FUNCTIONING MODE  

 

3.1 – Weight with enabled totalization   

If the users enables the totalization (menu SYSTEM -> TOTAL -> AB-TOT), it is possible to 
weigh consecutively and to progressively add up the values of each one.  
The  weight  placed  on  the  scale  is  added  up  to  the  total  actually  present  in  memory,  by 
pressing the key 

PRINT

If a printer is connected, a receipt is produced.  
100 weights maximum; after that the partial is printed. 

 
3.2 – Partial Total Printing / Multiple receipt closure  

it  is  possible  to  print  the  partial  total  (and  related  resetting)  pressing  the  key 

PRINT 

for  3 

sec.. If the multiple printing is active, the receipt gets closed.  

 

3.3 – Receipt reprinting   

It is possible to reprint a receipt, that has already been printed, pressing the key 

ENTER 

for 3 

sec.. 

 

3.4 – Partial Total Visualization  

After a sequence of weight, the user can ask for the visualization of the Partial total, which is 
to say the sum of the weights that have been done till that moment.  
If the key 

TOT

 is kept pressed, the screen alternatively shows the value of the total that has 

been memorized together with ”

T PAR

”.  

 

USER MENU ( USER ) 

 
Is is possible to access the menu voices through the prolonged pressure of the key 

MENU

 

4.1  CLOCK: Date and Time Setting  

The  device  LA715  has  a  calendar  clock  that  automatically  increases  even  without 

external power source. 
In this phase, it is possible to modify the current date and time.  

It is possible to access the indicated menu through the key 

ENTER. 

Press 

ENTER

 or 

DATE

 in order to modify the date, otherwise, press 

TIME

 to modify the time.  

The device shows the memorized value as day/month/year and hour/minute.  
Press 

ENTER

 to confirm the shown data or digit a new one, confirming then through 

ENTER

.  

 

4.2  ECONOM: Energy saving Mode setting   

As the device LA715 can optionally be endued with an internal rechargeable battery, in this phase, 
it is possible to program the best switch off / stand by mode, in order to guarantee the higher 
autonomy possible. 

 

In order to safeguard switching off option for the automatical sqitching off of the scale, after a 
period of inactivity.  
The possible choices are:

 

<RISPAR> within which it is possible to choose among: 

<NESSUNO>  Automatical squitching off off  

<A-OFF> 

Automatical switching off after x minutes of inactivity   

<STANDB>

 

The  standby  function  allows  to  save  the  charge  of  the  battery,  without 
completely  turning  off  the  indicator.  After  x  minutes  of  inactivity  of  the 
scale, the screen only shows some central flashing lines. Any pressure on 
the plate of the scale permits to go back to the usual funcioning.. 

<TIMER> It permits to set the number of minutes of inactivity  
 
 
 
 
 

Summary of Contents for LA715

Page 1: ...USER MANUAL WEIGHT INDICATOR MOD LA715 www odeca it...

Page 2: ...LED 6 digit display h 20 mm LED 4 Status LED KEYBOARD Touch keyboard with 12 keys LOAD CELL POWER SUPPLY 5Vdc 5 120mA max 8 load cell 350 Ohm LOAD CELL CONNECTION 6 wires with Remote Sense CASE Stainl...

Page 3: ...is on the weight is between 1 4 1 4 of zero If led is off the weight is steady If led is on the SW21 is working with internal battery if led is blinking the battery is low and need to be recharged thr...

Page 4: ...ion clear Tare PRINT 4 Print 3 sec pression Print total TOT 5 Display Total EXIT Esc ON OFF 6 On OFF 7 High resolution display 10 TARGET 8 Set target n 1 and n 2 9 Display Gross weight MENU 0 3 sec pr...

Page 5: ...s the key SET TARE 3 for 3 sec The Gross is shown once again and the signal led of the net weight turns off in order to confirm that the memorized tare has actually been cancelled 2 4 Visualization in...

Page 6: ...U 4 1 CLOCK Date and Time Setting The device LA715 has a calendar clock that automatically increases even without external power source In this phase it is possible to modify the current date and time...

Page 7: ...m the labelling machine the line added as verify is printed CANCEL Cancellation of what has been added 4 4 B TARA Tare Block It is possible to block the tare leeping it active after each operation 4 5...

Page 8: ...tifield enabling The Multifield operation allows to divide the weighing range of the scale into two or three 3000 div Each weighing subsets or into two 6000 div Each subsets It allows if the loading c...

Page 9: ...dmitted by the system in order to consider the weight stable The higher the number of divisions the lower the sensitivity Then the stability is more easily signalled Admitted values from 0 to 4 5 5 0...

Page 10: ...2 PERIF BAUD FRAME NOCOM ADDRES 6 2 USCITE USC 1 STATO PESO STABLE USC 2 STATO PESO STABLE 6 3 TOTAL AB TOT M TOT P MIN ABIL P 6 4 LINGUA 6 5 M FISC 6 6 NPROG 6 7 NO OFF 6 8 CALTAS 6 1 DEVICE Serial c...

Page 11: ...protocols on demand Setting Yes No if Yes is set it is possible to decide whether to visualize it fixed or flashing 6 2 3 ADRESS Programming address of the device from 0 to 99 If the address is 0 it i...

Page 12: ...n order to be able to print again The second one is a variation of weight a simple variation of weight allows to print again In the end no condition is necessary in order to print twice consequently T...

Page 13: ...LA715 12 User ManualP2640300...

Page 14: ...ells CONNESSIONE A 4 FILI 1 EXC ALIMENTAZIONE 2 EXC ALIMENTAZIONE 3 REF Cortocircuitare con morsetto 11 4 REF Cortocircuitare con morsetto 10 5 SIG SEGNALE 6 SIG SEGNALE ALIMENTAZIONE ALIMENTAZIONE SE...

Page 15: ...s C ZONA C 9 80129 m s SICILIA 2 SICILIA 2 9 79819 m s G NUM It can be manually added TABLE 2 Territorial Correspondence of the zones A B C SICILIA2 ZONA A ZONA B ZONA C ZONA SICILIA 2 EMILIA ROMAGNA...

Page 16: ...3 52 4 53 5 54 6 55 7 56 8 57 9 58 59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _...

Page 17: ...ity Direttiva CEE 89 336 sulla Compatibilit Elettromagnetica Norme Europee EN 55011 EN 50082 1 89 336 EU EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla si...

Page 18: ...and board If the instrument is sent through courier the costs of transport a r are in charge of the Customer The WARRANTY DECADES in case of breakdowns caused by interventions of not authorized peopl...

Reviews: