4.4 PREVENTATIVE MAINTENANCE, continued;
Preventative Maintenance, continued;
Hydraulic Fluid and Filter:
The hydraulic fluid and filter should be
changed every 100 hours of operation. The fluid should be completely
drained and fresh high quality hydraulic fluid should be added.
Exhaust Duct Gasket:
The 1.5" thick gasket should be checked for
wear every 200 hours. This gasket creates a tight seal between the box
container and the blower housing.
Axle Hangers:
The hanger bolts should be checked periodically for
tightness and wear.
Hydraulic Fittings:
Check all hydraulic fittings for leaks and tightness.
Any leak could become a hazard, fix immediately.