Chapter 4 Bios Setup
Hippo DCA2 User’s Manual
27
CHAPTER 4
BIOS SET UP
4.1
BIOS Power-On Self-Test (POST)
During the self-test, errors may occur. These errors are communicated through a series of
beeps. The method of beeps used depends on the BIOS program. For example, Microid
Research BIOS uses a combination of low and high tones. AMI BIOS uses a series of
beeps with different error messages that correspond to the number of beeps heard.
4.2
AMI BIOS Error Beep Codes
# of Beeps
Error Message
Explanation
1
DRAM Refresh Failure
The memory refresh circuitry is faulty
2
Parity Error
A parity error occured in the first 64KB
block of memory
3
Base 64K RAM Failure
A memory failure occurred in the first
64KB of memory
4
System Timer Failure
Timer 1 is not functioning
5
Processor Failure
An error occurred in the CPU
6
Gate A20 Failure
The BIOS is unable to switch the CPU
into protected mode
7
Processor Exception Error
An exception interrupt occured in the
CPU
8
Display Memory Read/Write
Error
The system video adapter is missing or
its memory is faulty
9
ROM Checksum Error
The ROM checksum value does not
match the BIOS code
10
Read/Write Error
The CMOS shutdown register memory
has failed
4.3
Microid Research BIOS Error Beep Codes