octagon v2.16
Page 45
5.
MODIFICATION OF THE MAXIMUM POWER OF THE BURNER IN TWO STEPS
5.1.
ADJUSTMENT OF FAN SPEED, 2
nd
CONFIGURATION LEVEL
The speed levels per power rating are subject to the following parameters:
FAN SPEED
PARAMETER
Fan speed during phase FIRE STOP
19
Fan speed during phase TEST FIRE
20
Fan speed at Power 1
24
Fan speed at Power 5
28
ADJUSTMENT OF SPEED (CONTINUATION OF Νο 4), ACCESS TO PROGRAMMING
BUTTON
INDICATION
SCREEN DISPLAY
ΟΝ
+, -
PARAMETERS
[ 8 ]
ENTER
PARAMETER SETTINGS
Par - - - -
+, -
PARAMETER SETTINGS
DESIRED PARAMETER
ENTER
SELECTED VALUE
5.2.
ADJUSTMENT PELLET FEEDING-AUGER, 2
nd
CONFIGURATION LEVEL
This procedure is the same as with the adjustment of the fan.
By adjusting only the ON time of the auger, the burner will calculate automatically the OFF time.
Choose parameter.
AUGER OPERATION
PARAMETER
Power 1 = Auger ON
10
Power 5 = Auger ΟΝ
18