background image

19 August 2021

 

All dimensions are in mm

 

Copyright

 

1

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

 

Gas Log Lighters for Wood Fires

 

Installation and Operational Instructions

 

Gas Starter Log Lighters

 

1.   FOR WARMINGTON SI / SN SERIES FIRES:

 

2.  FOR WARMINGTON TF SERIES FIRES: 

 

Warmington gas log lighters are constructed and tested to comply with NZS 4558(int):2013 

Decorative gas log and 

other fuel effect appliances

”.

 

Keep these instructions for further reference. Ensure that you have the correct and current installation details.

 

IMPORTANT 

Read all the instructions carefully before commencing the installation. Failure to follow these instructions may result in a fire hazard and void the warranty. 

1A:  SI/SN FLARE

 

1B:  SI/SN RAIL BURNER

 

1C:  SI/SN TEE BAR RAIL BURNER

 

2A:  TF FLARE

 

2B:  TF TEE BAR RAIL BURNER

 

Summary of Contents for SI Flare

Page 1: ...TF SERIES FIRES Warmington gas log lighters are constructed and tested to comply with NZS 4558 int 2013 Decorative gas log and other fuel effect appliances Keep these instructions for further referenc...

Page 2: ...ement Warmington Ind LTD reserves the right to change product specifications without prior notification COMPONENTS REQUIRED FOR INSTALLATION Supplied No Burner Head only one type is supplied 1 Control...

Page 3: ...use a registered gas fitter for installation and maintenance work of gas components Always use a registered electrician for installation and maintenance work of electrical components If using cylinde...

Page 4: ...the Warmington factory If retrofitting into an existing fire follow these instructions Even if the unit comes with the firebox the heatshield has to be prepared for the gas feed and spark rectifier w...

Page 5: ...side of a TF fire There is a left hand and right hand version of the TF flare Please ensure the correct version is on site before installing OPTION B SI SN RAIL BURNER Description 600 Rail Burner LH...

Page 6: ...installing into Warmington SI and SN fires For new installations rail burner head will come pre mounted Route gas and electrical feeds as appropriate For retrofitting cut holes in firebox and ash pan...

Page 7: ...nted for before installing the unit There is a removable access plate on the top of the housing for servicing For new installations Plan ahead for where the tee bar will sit in relation to the brick o...

Page 8: ...All gas flares or rails used for domestic and commercial purposes shall be firmly secured unless defined as portable or mobile to prevent dislodgement from their point of fixture or installation Such...

Page 9: ...5 After checking adjusting the pressure turn the unit off remove manometer from the test point and tighten the test point screw Ensure to check for gas leaks 6 Turn the appliance on and off a few tim...

Page 10: ...t 2021 All dimensions are in mm Copyright 10 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification WIRING DIAGRAM Pulse...

Page 11: ...y and not installed where moisture could build up or affect the electronics Scenario 4 The flame burns well away from the burner head Check the correct jet for the gas supply LPG NG Check the gas pres...

Page 12: ...T IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTION CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER...