INSTALLATION
| Specification
BIA-EUROPA Mini IWP-EN12 | www.ochsner.com 35
EUROPA Mini IWP
COMPRESSOR:
Type
Rotary piston
Quantity
[pcs]
1
Output levels
1
Start type
[rpm]
Direct
Phases / voltage / frequency
[V]/[Hz]
1/220-240 / 50
REFRIGERANT CIRCUIT:
No. of refrigerant circuits
[pcs]
1
Heat transfer medium
R134a
Refrigerant full charge
[kg]
0,53
FAN:
Type
Radial fan
Quantity
[pcs]
1
Phases / voltage / frequency
[V]/[Hz]
1/220-240/50
Power consumption
[W]
68
Max. operating current
[A]
1,40
Unrestricted air flow
[m³/h]
360-510
Infinitely variable
built-in
External pressure
[Pa]
80
EVAPORATOR:
Type
Finned tube heat exchanger
Material
Copper/aluminium
Quantity
[pcs]
1
Defrost technology / frost protection shutdown
Hot gas
Max. refrigerant operating pressure
[bar]
25
Operating temperature min.
[°C]
-10
Operating temperature max.
[°C]
+40
14.2 Controller
Tiptronic Plus S (touchscreen)
ANALOGUE INPUTS:
F1
PTC, type KTY81-121
DHW tank temperature, centre, control temperature (colour: blue)
F2
PTC, type KTY81-121
DHW tank temperature, top, indicated temperature (colour: green)
F3
PTC, type KTY81-121
Evaporator (colour: yellow)
F4
PTC, type KTY81-121
Solar collector temperature (colour: red)
Measuring range
KTY81-121: -50-150°C
DIGITAL INPUTS:
E1
In the event of a high pressure alarm, the HP switch interrupts the relay coil, approx. 140 mA
E2
Function freely selectable (see parameter b13)
E3
Function freely selectable (see parameter b15)
SWITCHED OUTPUTS:
K1
Relay, 30 (9) A / 250 V~
Compressor
K2
Relay, 16 (2.2) A / 250 V~
Electric heater (approx. 1.6 kW)
K3
Relay, 16 (2.2) A / 250 V~
Inrush 120 A (20 ms) pump
K4
Relay, 16 (2.2) A / 250 V~
Solenoid valve
K5
TRIAC actuator, 3 A / 250 V~
Fan
REAL TIME CLOCK:
Accuracy 50 pmm (error max. 5 seconds per day), battery buffering by Gold-Cap up to 3 days.
In the event of a longer power failure, the clock must be reset.