Configuration pages:
In the configuration pages, the -10 and +10 keys are used to change the
active line (up and down), and -1 and +1 keys to change the parameter
value.
Configurable parameters:
Power Off
– Time for auto power off. Value of 1 to 10 minutes.
Disp Contrast
– Display contrast. Value from 1 to 9.
Anchor act
– Activation of the anchor windlass control page. ON / OFF
values.
Beep
– Activating the Beep . ON/OFF values.
Depth Offs
– “Depth offset”. It is the depth where the sensor is placed.
The value can be from 0 to 5 meters (15 feet), with 0.1m (0.5 feet)
increments.
Units
– Units for the depth gauge. Meters or feet.
Local time
– Is the time difference between standard time and UTC. It
will be negative (W) or positive (E) to Greenwich meridian.
Link with Base
– Initial link establishment with the base station. It is
required for the automatic setup of the communication channel with
the ATM105A. It must be performed the 1st time the remote is used.
Technical data:
Power voltage: 3,7V DC
Battery capacity: 450mAh.
Maximum consumption: 20mA with maximum backlight.
11mA without backlight.
10nA in standby.
Average charge time: 2h.
Average autonomy without charge: 1 month with a normal daily use of
8-10 hours.
Display: LCD monochrome graphic. 128x64 pixels.
Maximum radio range: 15m. (Without obstructions).
Frequency band: 2,4Ghz.
Channels (automatic search): 126.
Transmission power: 1mW. (0dB).