3.2
Handling and positioning of the device
To position the device correctly, take the following aspects into consideration:
●
Access to the unit from the front side must be guaranteed to make operation and maintenance procedures
easy.
●
The constant current regulators can be arranged side by side or stacked one on top of the other (up to a
maximum of 3) to optimise floor space. Attention: stacking is the responsibility of the Manufacturer and must
be requested in the article code when ordering.
●
Maintain a free space of at least 20 cm at the rear side of the unit to ensure proper ventilation of the device.
Before proceeding with the operation, check the conditions of the device:
●
check that the mechanical fixing of the components are steady;
●
check that the internal connections are properly tightened;
●
check that the internal equipotential connections are all well realized.
Always use lifting equipment of suitable characteristics: before handling the load, check
the weight and dimensions of the load to be lifted, verifying the correct positioning of the
centre of gravity.