Troubleshooting
6.1 TROUBLESHOOTING PROBLEMS AND THEIR SOLUTIONS
The X-Series is fitted with an advanced diagnostic indicator system. The X-Series X4 Colours have one small orange
diagnostic LED, while the rest of the X-Series lights have two small indicator LEDs (one red and one orange) within the
unit, visible through the front lens.
X-Series X4 Colours (One Diagnostic LED):
When the X-Series X4 Colours unit is first turned on, the single orange diagnostic LED will flash briefly. This is normal
operation and is part of the start-up procedure, to show that the LED is functioning. During normal operation the
diagnostic LED should not be illuminated.
The table below summarizes the detected fault modes:
X-Series - X4 Colours
Orange LED
Main LEDs
CHECK
On
Off
Input voltage is too low
– less than ~9V. Check voltage of power source and cabling for bad
connections and rectify.
Flashing
Off
Input voltage is too high
– above ~32V. Check voltage of the power source and rectify.
Quick Flash
Off
Unit has detected a fault with the wiring, or the power source is not capable of supplying the
required current. The input voltage is dropping below the minimum allowed during start-up.
After five start-up attempts the unit will shut down and both indicator LEDs will flash
continuously. This could be due to a poor power source (e.g., discharged battery) or voltage
drops caused by poor connections or incorrect wire gauge.
On
On
Internal fault detected with temperature sensor
– if this issue persists contact your dealer.