6.2 CABLE GAUGE CHART 24V 

 

Supply & Return Cable Conductor Size Chart 3% drop for when using 24V DC supply

 

Cable 
length 
(feet)*

 

Circuit Current

 

 

2 Amp

 

4 Amp

 

6 Amp

 

8 Amp

 

10 Amp

 

15 Amp

 

20 Amp

 

25 Amp

 

30 Amp

 

40 Amp

 

50 Amps

 

0-5

 

18 AWG

 

18 AWG

 

18 AWG

 

18 AWG

 

18 AWG

 

16 AWG

 

14 AWG

 

14 AWG

 

12 AWG

 

12 AWG

 

10 AWG

 

5-10

 

18 AWG

 

18 AWG

 

16 AWG

 

16 AWG

 

14 AWG

 

12 AWG

 

12 AWG

 

10 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

10-15

 

18 AWG

 

16 AWG

 

14 AWG

 

14 AWG

 

12 AWG

 

12 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

15-20

 

18 AWG

 

16 AWG

 

14 AWG

 

12 AWG

 

12 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

20-25

 

18 AWG

 

14 AWG

 

12 AWG

 

12 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

25-30

 

16 AWG

 

14 AWG

 

12 AWG

 

10 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

30-35

 

16 AWG

 

14 AWG

 

12 AWG

 

10 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

35-40

 

16 AWG

 

12 AWG

 

10 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

40-45

 

14 AWG

 

12 AWG

 

10 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

45-50

 

14 AWG

 

12 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

50-55

 

14 AWG

 

12 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

55-60

 

14 AWG

 

10 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

60-65

 

14 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

65-70

 

14 AWG

 

10 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

70-75

 

12 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

2 AWG

 

0 AWG

 

2/0

 

AWG

 

75-80

 

12 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

2/0

 

AWG

 

80-85

 

12 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

2/0

 

AWG

 

85-90

 

12 AWG

 

10 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

2/0

 

AWG

 

90-95

 

12 AWG

 

8 AWG

 

8 AWG

 

6 AWG

 

4 AWG

 

4 AWG

 

2 AWG

 

1 AWG

 

1 AWG

 

2/0

 

AWG

 

2/0

 

AWG

 

95-100

 

12 AWG

 

8 AWG

 

6 AWG

 

6 AWG

 

4 AWG

 

2 AWG

 

2 AWG

 

1 AWG

 

0 AWG

 

2/0

 

AWG

 

3/0

 

AWG

 

 

*One-way cable length from supply (usually battery) to load. 

 

Summary of Contents for Sport S3116d

Page 1: ...LIGHT YEARS AHEAD WWW OCEANLED COM OceanLED MANUAL SPORTS SERIES DOCKLIGHT REVISION 8 4 INSTALLATION OPERATION MANUAL SPORTS SERIES DOCKLIGHT...

Page 2: ...ANLED INSTALLATION 14 4 Operation Maintenance 15 4 1 DUAL COLOUR OPERATION 15 4 2 SPORT DUAL COLOUR CONFIGURATION MODE 15 4 3 SPORT MULTI COLOUR CONTROL WITH DC SWITCH OPERATION 16 4 4 MAINTENANCE 16...

Page 3: ...salt water Some OceanLED lights contain combinations of plastic and polymer products which are impervious to salt water corrosion however screws and fasteners used for the installation must be of a m...

Page 4: ...used for illuminating the waters around marinas and waterways Best placement for achieving the best results are described in selecting the right location IMPORTANT NOTICE Attention Installer This manu...

Page 5: ...ge and to ensure the power supply is not overworked causing premature failure Use chart below in determining power supplies 2 3 POWER CONSUMPTION AND RECOMMENDED FUSE VALUES IDENTIFYING YOUR MODEL Sin...

Page 6: ...ns storms seasons and the overall desired effect when designing your installation Depth Fixed Piling or Bulkhead Ideally mount your lights at similar depth levels to ensure matching colour consistency...

Page 7: ...f the water clear water 10 feet 3 meters dirty water 5 feet 1 5 meters and considering the overall design of the installation SPACING INSTALL DEPTH SPORTS SERIES DOCKLIGHT Recommended Spacing 1 5m 3m...

Page 8: ...er than those described in this guide will invalidate its warranty Any incorrectly bonded conduit pipes to the dock light support that allow water ingress will not be covered under warranty Please do...

Page 9: ...plied Tee adaptor feeding the cable through the 90 threaded exit pipe and bond in pace in the required orientation using PVC solvent weld adhesive ensuring that the joint is fully watertight Bond Cond...

Page 10: ...he Tee adaptor and screw on the conduit cap gland ensuring that the joint is fully watertight Fit Conduit Cap with Cable Gland Ensure threaded joint is sealed 6 Tighten the cable gland to ensure a wat...

Page 11: ...kLight Install Manual It is important to ensure the conduit is fully sealed to stop water ingress into the unit All connections should also be fully sealed including sealing the outer cable jacket as...

Page 12: ...hts to reduce load on the switch and voltage drops caused by long cable runs to the switch location For complete instructions on vDC connections please refer to The National Electric Code and consult...

Page 13: ...SPORTS SERIES DOCKLIGHT INSTALL OPERATION MANUAL 12 FUSE KIT CONNECTION OVERVIEW EXAMPLE CONNECTION DIAGRAM SINGLE DUAL COLOUR SPORTS SERIES DOCKLIGHT KIT INCLUDES Fuse Kit...

Page 14: ...r a connection example All relays should be at least 20A contact rated normally closed type Pressing switch should disconnect supply to lights POWER SUPPLY REQUIREMENTS A suitably fused 24v supply is...

Page 15: ...the connected lights and should be sized correctly to prevent excessive voltage drop and power loss The cables from the power junction box to the lights themselves can be a smaller gauge but again sh...

Page 16: ...turn light s back on again 5 Repeat steps 2 4 another 4 times If the light changes mode on re power up then the light has not been turned off for long enough in step 4 6 On the 5th power up the light...

Page 17: ...Green Blue Red Green then repeat 4 4 MAINTENANCE Sea growth can collect quickly on the light and this can reduce the performance in just a few weeks To prevent the build up of sea growth all OceanLED...

Page 18: ...if water is present inside the light Water present If water is present contact your dealer Typically this is due to water penetration via the cable due to poor connection or damaged cable Light does n...

Page 19: ...SPORTS SERIES DOCKLIGHT INSTALL OPERATION MANUAL 18 6 Appendix 6 1 OVERALL DIMENSIONS PHYSICAL Total Weight 1 2kg Cable Length standard 32 8 10m In line Fuse Kit 0 5 12 5mm...

Page 20: ...SPORTS SERIES DOCKLIGHT INSTALL OPERATION MANUAL 19 OVERALL DIMENSIONS OPTIONAL DOCKLIGHT FLOATING KIT...

Page 21: ...2 AWG 10 AWG 10 AWG 8 AWG 6 AWG 6 AWG 4 AWG 4 AWG 2 AWG 2 AWG 40 45 14 AWG 12 AWG 10 AWG 10 AWG 8 AWG 6 AWG 4 AWG 4 AWG 4 AWG 2 AWG 2 AWG 45 50 14 AWG 12 AWG 10 AWG 8 AWG 8 AWG 6 AWG 4 AWG 4 AWG 2 AWG...

Page 22: ...SPORTS SERIES DOCKLIGHT INSTALL OPERATION MANUAL 21 NOTES...

Page 23: ...Reserved Specifications are subject to change without notice Trademarks are the property of Ocean LED Marine LTD www oceanled com Ocean LED Marine LTD Ocean LED USA LLC Unit 1 Jacknell Road Dodwells...

Reviews: