5.8
OCEANDMX JUNCTION BOX CONNECTIONS:
NAME
FUNCTION
CONNECTION
PWR IN
+
DC POWER +VE
CONNECT TO A FUSED +12/+24 VDC FROM
FUSE PANEL / BATTERY
-
DC POWER -VE
CONNECT TO BATTERY GND RETURN
CONTROL
INPUT /
OUTPUT
PWR
SW
POWER SWITCH
CONNECT TO (RED)
GND
DMX GND
CONNECT TO DMX GND (BLACK)
DMX+
DMX CONTROL VE
CONNECT TO DMX+ (YELLOW)
DMX-
DMX CONTROL SIGNAL -VE
CONNECT TO DMX- (BROWN)
SHIELD
CABLE SHIELD CONNECTION
CONNECT TO CABLE SHIELD / SCREEN IF
AVAILABLE
LIGHT ‘X’
OUTPUT
(‘X’ CAN RANGE
FROM 1- 4)
+VE
LIGHT ‘X’ +VE
CONNECT TO LIGHT +VE (RED)
GND
LIGHT ‘X’ -VE
CONNECT TO LIGHT -VE (BLACK)
DMX+
DMX CONTROL VE
CONNECT TO LIGHT DMX+ (YELLOW)
DMX-
DMX CONTROL SIGNAL -VE
CONNECT TO LIGHT DMX- (BROWN)
SHIELD
CABLE SHIELD CONNECTION
CONNECT TO LIGHT CABLE SHIELD / SCREEN
IF AVAILABLE
DMX
TERMINATOR
ON
DMX TERMINATION ON
SWITCH ON TO TERMINATE DMX SIGNAL (LAST
JUNCTION BOX IN CHAIN)
OFF
DMX TERMINATION OFF
SWITCH OFF TO CONTINUE DAISYCHAINING
OTHER JUNCTION BOXES
X Series light cables must not be extended
Installation (X Series)
21
2 0 1 9 I N S TA L L & O P E R AT I O N M A N U A L
CONTROLLER
KITS