CONNECTIONS OVERVIEW:
Item
Function
A
DMX Out
B
DMX In/Out
C
NMEA2000 / Power (12/24V)
D
Ethernet
E
Audio In
F
Audio Out
G
Switch Input
H
Diagnostic LEDs
I
Test/Reset Switch
J
USB Port (Memory Stick only)
Diagnostic LEDs (H):
ID
LED
STATUS
1
Green - ON
Unit operating properly
2
Amber - ON
Reading Devices (RDM mode)
3
Red - ON
Overheating
4
Amber, Green, Red - ON
Loading System
5
Green, Red - ON
Factory Reset Initialized
Test/Reset Switch (I):
ID SWITCH
FUNCTION
1
Press once (short press)
Test Mode – The unit will execute power on sequence on all
connected devices
2
Press and hold until Amber LED ON (approx. 5s)
Reboot/Reload the OceanBridge App
3
Press and hold until Red LED ON (approx. 30s)
Factory Reset – All data and settings will be erased
DIMENSIONS
Ocean LED Marine LTD / Tel +44 (0) 1455 637505 / [email protected]
Ocean LED USA LLC / Tel +1 954 523 2250 / [email protected] /
www.oceanled.com
Specifications are subject to change without notice.