![Oceanic VT 3 Operating Manual Download Page 157](http://html1.mh-extra.com/html/oceanic/vt-3/vt-3_operating-manual_3328967157.webp)
157
OPERATIONAL PERFORMANCE
Function:
Accuracy:
•
Depth
±1% of full scale
•
Timers
1 second per day
Dive Counter:
•
NORM/GAUG displays Dives #1 to 24, FREE displays Dives #1 to 99 0 if no dive made yet
•
Resets to Dive #1, upon diving (after 24 hours with no dives)
NORM/GAUG Dive Log Mode:
•
Stores 24 most recent NORM/GAUG dives in memory for viewing
•
After 24 dives, adds 25th dive in memory and deletes the older dive
Altitude:
•
Operational from sea level to 14,000 feet (4,270 meters) elevation
•
Measures ambient pressure every 30 minutes when not activated, upon activation by push button, and every 15
minutes while in NORM/GAUG/FREE Surface Modes.
•
Does not measure ambient pressure when Wet.
•
Compensates for Altitudes above sea level beginning at 3,001 feet (915 meters) elevation and every 1,000 feet
(305 meters) higher.
Conservative Factor:
•
Reduces NORM and FREE NDLs to those for the Altitude 3,000 feet (915 meters) higher.
Power:
• VT3 Battery
1 - 3 vdc, CR2450, Lithium battery
• Transmitter Battery
1 - 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
• Shelf life
Up to 5 years
• Replacement
User replaceable (annual recommended)
• Use Life (VT3)
1 year or 300 dive hours if 2 - 1 hour dives per dive day
• Use Life (Transmitter)
300 dive hours if 2 - 1 hour dives per dive day