![Ocean OWDI 9614 WT S Service Manual Download Page 40](http://html2.mh-extra.com/html/ocean/owdi-9614-wt-s/owdi-9614-wt-s_service-manual_5137961040.webp)
Page 40
8.8 Door Lock*
The type of door lock is the solenoid fixed hook
door lock. Since the locking could be done with the fixed
hook, door handle is not used on model. The door is
opened at the end of the program and also as long as
the condition of the water level and temperature in the
drum is safe, door could be open.
In order to intervene to the door lock in emergency
cases, the door could be opened by pulling the
emergency handle which placed under the pump cover.
But the user needs to be make sure that the water level
and temperature condition in the drum is safe.
Door lock
Technical features
Nominal voltage (Rated)
170 - 250 V
Current (Rated)
16 (6) A
Testing component
Check the resistance value on the component with multi-meter as shown in below figures. Resistance value on
the (PTC ov solenoid) should be 240Ω ±20% at 25 °C. That resistance value can be measured from
terminal 3-4 (refer to section12 Wiring Connection Diagram).
This socket shows the connection between terminal 3-4 (See wiring diagram below). The resistance read from
terminal 3-4 is the resistance of PTC overload plus resistance of solenoid.
3
4
5