![Ocean OWDI 9614 WT S Service Manual Download Page 34](http://html2.mh-extra.com/html/ocean/owdi-9614-wt-s/owdi-9614-wt-s_service-manual_5137961034.webp)
Page 34
8.2 Circulation Pump*
The component is used for circulation of water
inside the drum in order to increase washing
performance.
Circulation Pump
Technical features
Nominal voltage
220 - 240 V
Frequence
50 Hz
Resistor (ci)
169,5 Ω (±5%)
Testing component
Check the resistance value on the component with multi meter as shown below.
Resistance value should be between 160- 180 Ω
You can determine the ohm value by measuring from the red cable at 5th and red cable at 12th
position in the small socket (refer wiring diagram in section 12) as shown below figure. Resistance
value should be between 160- 180 Ω