5.1.3. SCAN_MODE
This parameter is used to further define the behavior of scan mode.
Bit:
7
6
5
4
3
2
1
0
Function
PREFIX_E
TERM_
E
-
FORMAT-
SCAN_LOCK_T
IME
DATA
default
b0
b0
b0
b0
b00
b00
DATA:
Defines which data are output in scan mode
b00:
Serial no.
b01:
Data block
The data block defined by DB_ADR, D_LGT and D_START is output.
b10
- reserved -
b11
- reserved -
SCAN_LOCK_TIME
This parameter defines the time for which the transponder is locked by the reader for
further processing. Only when the transponder has left the detection zone of the
reader for SCAN_LOCK_TIME are its data output again.
b00:
0 sec
With this setting the data are output continuously as fast as they are read
from the transponder.
b01:
0.5 sec
b10:
1.0 sec
b11:
2.0 sec