OBID
®
Manual
ID RW01L.AB-A
FEIG ELECTRONIC GmbH
Page 13 of 39
H20801-1e-ID-B.doc
Data format:
Start bit:
1
Data bit:
8
Stop bit:
1
Parity:
even (default)
No
Timing:
•
Protocol start gap:
Before the start character (length byte) of the protocol a time gap of at least 5 ms must be
maintained.
Host
→
Reader:
..
Response time
Start gap
..
..
Õ
5...n ms
Ö
Õ
min. 5 ms
Ö
Host
←
Reader:
..
..
..
•
Data timeout:
Within a protocol the characters must follow at an interval of max. 12 ms.
Õ
max. 12 ms
Ö Õ
max. 12 ms
Ö Õ
max. 12 ms
Ö
Host
→
Reader:
Char n
Char n+1
Char n+2
..