4. Commands for reader control and configuration
4.1. [0x62] CONFIG_READ
The command CONFIG_READ can be used to read the current configuration of the reader block by
block. The configuration is stored in a block with 14 bytes (see also
Host
→
Reader:
1
2
3
4
5
5
COM-Adr
[0x62]
CFG_ARD
CSUM
Host
←
Reader
1
2
3
4
5...18
19
19
COM-Adr
[0x62]
CFG (14 Byte)
CSUM
CFG_ADR:
Address of the configuration block you want to read.
CFG:
Configuration block
4.2. [0x82] CONFIG_WRITE
The command CONFIG_WRITE is used to save a configuration block in the reader.
Host
→
Reader:
1
2
3
4
5...18
19
19
COM-Adr
[0x82]
CFG_ADR
CFG
CSUM
Host
←
Reader:
1
2
3
4
5
5
COM-Adr
[0x82]
CSUM
CFG_ADR:
Address of the configuration block you want to read.
CFG:
Configuration block
NOTE:
In order for the reader to work with the modified configuration, you must perform a reset on the
reader after saving a modified configuration (e.g.,
1
see
APPENDIX B: List of status bytes
2
see
APPENDIX B: List of status bytes